摘要
Aim. An evaluation of foot pressure distribution during the operation of four dental foot pedal controllers each with its own working principle, the universal pedal controller (A-dec), combined sliding pedal controller (KaVo), pedal controller (Sirona) and sliding wheel controller (XO CARE) was carried out. Material and methods. A total of 63 subjects (31 female and 32 male) participated in this study. The in-shoe measuring system from medilogic (Schonefeld, Germany) was used to record the pressure distribution of the working and the supporting leg during the operation of the foot controllers. The foot pressure distribution of both feet was measured while regulating the speed. For the statistical evaluation of the maximum and average pressures of the six zones of the foot the Friedman test and a Bonferroni-Holm correction were used. Having finished the test, the subjects were asked to fill out a questionnaire to score the operating principles of each foot pedal. Results. There were significant differences among the medium and maximum pressure values of the working and supporting leg. The foot pressure (among the six measured zones) was determined relatively by the operating principles of the foot pedals. The highest pressure values occurred on the heel using a foot controller which has the pedal function. Regarding the rating of the working principles of the foot controllers (1 best 4 worst), the sliding wheel controller ranked best followed by the combined sliding pedal controller, the universal pedal controller and the pedal controller. Conclusion. There was an increased pressure load on the flexion and extension movement of the working leg when operating the universal pedal controller, the pedal controller and the combined sliding pedal controller. In turn, the universal pedal controller and the pedal controller caused a reduction of the load on the supporting leg by muscular compensation functions in terms of shifting the weight. Thus, accustomed working sequences have a negative impact on the movement system and should therefore be included in a manual therapeutic examination and therapy.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 50 条
  • [1] Untersuchung der Fußdruckverteilung des zahnärztlichen FußanlassersEvaluation of foot pressure distribution on dental foot pedals
    C. Gerhard
    D. Ohlendorf
    W. Betz
    S. Kopp
    Manuelle Medizin, 2011, 49 (2) : 99 - 106
  • [2] Evaluation verschiedener Funktionsprinzipien des zahn -ärztlichen Fußanlassers hinsichtlich der FußdruckverteilungExamination of the foot pressure distribution regarding to various functional principles of a dental foot controller
    Caroline Gerhard
    Daniela Ohlendorf
    Werner Betz
    Stefan Kopp
    Zentralblatt für Arbeitsmedizin, Arbeitsschutz und Ergonomie, 2011, 61 (7) : 220 - 229
  • [3] The Study of Correlation between Foot-pressure Distribution and Scoliosis
    Park, J. H.
    Noh, S. C.
    Jang, H. S.
    Yu, W. J.
    Park, M. K.
    Choi, H. H.
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 974 - 978
  • [4] PVDF Sensors - Research on Foot Pressure Distribution in Dynamic Conditions
    Klimiec, Ewa
    Zaraska, Wieslaw
    Piekarski, Jacek
    Jasiewicz, Barbara
    ELECTROACTIVE POLYMERS: ADVANCES IN MATERIALS AND DEVICES, 2013, 79 : 94 - +
  • [5] The effect of triceps surae contracture force on plantar foot pressure distribution
    Aronow, MS
    Diaz-Doran, V
    Sullivan, RJ
    Adams, DJ
    FOOT & ANKLE INTERNATIONAL, 2006, 27 (01) : 43 - 52
  • [6] Muscle strength and foot pressure vary depending on the type of foot pain
    Lee, Jin Hyuck
    Hwang, Jangsun
    Park, Hyungyu
    Kang, Hyunoh
    Song, Wonkyu
    Choi, Doo-Ah
    Seong, Cheul-Hun
    Jang, Woo Young
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [7] Calibration of optical foot pressure systems
    Franks, CI
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (01) : 69 - 72
  • [8] EVALUATION FRAMEWORK ON TRANSLATION-INVARIANT REPRESENTATION FOR CUMULATIVE FOOT PRESSURE IMAGE
    Zheng, Shuai
    Huang, Kaiqi
    Tan, Tieniu
    2011 18TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2011, : 201 - 204
  • [9] A state-of-the-art review of foot pressure
    Zulkifli, Siti Syazni
    Loh, Wei Ping
    FOOT AND ANKLE SURGERY, 2020, 26 (01) : 25 - 32
  • [10] Fatigue Estimation Using Foot Pressure Sensors
    Tanaka, Isamu
    Terada, Shuhei
    Tsuchiya, Ryuichi
    Hanawa, Dai
    Oguchi, Kimio
    2013 36TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING (TSP), 2013, : 600 - 602