OPTICAL-ROTATION TECHNIQUE USED FOR A HIGH-PRECISION MEASUREMENT OF PARITY NONCONSERVATION IN ATOMIC LEAD

被引:32
|
作者
MEEKHOF, DM [1 ]
VETTER, PA [1 ]
MAJUMDER, PK [1 ]
LAMOREAUX, SK [1 ]
FORTSON, EN [1 ]
机构
[1] UNIV WASHINGTON, DEPT PHYS, FM-15, SEATTLE, WA 98195 USA
来源
PHYSICAL REVIEW A | 1995年 / 52卷 / 03期
关键词
D O I
10.1103/PhysRevA.52.1895
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We have measured the parity-nonconserving (PNC) optical rotation near the 1.279-mu m P-3(0) --> P-3(1) magnetic-dipole absorption line in atomic lead vapor. We measure the quantity R = Im (epsilon(PNC)/M), where M is the magnetic-dipole amplitude of the absorption line and epsilon(PNC) is the electric-dipole amplitude coupled into the same line by the PNC interaction within the lead atom. We find R to be (-9.86+/-0.04+/-0.11) x 10(-8), where the first error is statistical and the second is systematic. The statistical errors are due to incompletely subtracted background fluctuations, and the systematic errors are caused by line-shape uncertainties and calibration error. Our value is consistent with the atomic PNC calculations for lead, which give R = (-10.7+/-0.8)x 10(-8) for the standard electroweak model with sin(2) theta(w) = 0.23 and no electroweak radiative corrections. Including radiative corrections yields the value S = -3 +/- 8 for the isospin-conserving electroweak parameter, with difficulties in the atomic theory of lead presently limiting the extent to which our result tests the standard model. This same technique can also be applied to thallium, where the atomic theory is currently accurate to 3%. By searching for a difference in a for the two hyperfine components of Pb-207, we find the amplitude of the nuclear spin-dependent PNC rotation to be less than 2 x 10(-2) of the nuclear spin-independent rotation.
引用
收藏
页码:1895 / 1908
页数:14
相关论文
共 50 条
  • [31] A high-precision centering and undeformed cementing technique for optical lens
    Wu, F
    Yang, L
    Wu, SB
    Cheng, Q
    ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGY 2000, 2000, 4231 : 170 - 174
  • [32] Combined fabrication technique for high-precision aspheric optical windows
    Hu, Hao
    Song, Ci
    Xie, Xuhui
    ADVANCES IN OPTICAL AND MECHANICAL TECHNOLOGIES FOR TELESCOPES AND INSTRUMENTATION II, 2016, 9912
  • [33] Repeated Loading Error Measurement of High-Precision Optical Sight
    Xu Zhigang
    Zhao Yuanyuan
    Zhou Liang
    LASER & OPTOELECTRONICS PROGRESS, 2019, 56 (02)
  • [34] Method of realization of high-precision measurement of lengths of optical fibre
    Machekhin, Yuri P.
    Raschektayeva, Angelika I.
    LFNM 2006: 8TH INTERNATIONAL CONFERENCE ON LASER AND FIBER-OPTICAL NETWORKS MODELING, PROCEEDINGS, 2006, : 228 - +
  • [35] Rotation error measurement technology and experimentation research of high-precision hydrostatic spindle
    Ma, Ping
    Zhao, Chunming
    Lu, Xinhui
    Gong, Chenglong
    Niu, Xing
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2014, 73 (9-12): : 1313 - 1320
  • [36] Rotation error measurement technology and experimentation research of high-precision hydrostatic spindle
    Ping Ma
    Chunming Zhao
    Xinhui Lu
    Chenglong Gong
    Xing Niu
    The International Journal of Advanced Manufacturing Technology, 2014, 73 : 1313 - 1320
  • [37] Influence of inhomogeneity of optical glass used in high-precision optical system on imaging quality
    Cen, Z.-F. (cenzf@zju.edu.cn), 1600, Chinese Optical Society (42):
  • [38] Achieving High-Precision Attenuation Coefficient Measurement in Optical Coherence Tomography
    Neubrand, Linda B.
    Attendu, Xavier
    van Leeuwen, Ton G.
    JOURNAL OF BIOPHOTONICS, 2025, 18 (03)
  • [39] Achieving High-Precision Attenuation Coefficient Measurement in Optical Coherence Tomography
    Neubrand, Linda B.
    Attendu, Xavier
    van Leeuwen, Ton G.
    Journal of Biophotonics,