A COMPARISON OF ROOT-CANAL PREPARATIONS USING NI-TI HAND, NI-TI ENGINE-DRIVEN, AND K-FLEX ENDODONTIC INSTRUMENTS

被引:312
作者
GLOSSON, CR
HALLER, RH
DOVE, SB
DELRIO, CE
机构
[1] WILFORD HALL USAF MED CTR,DEPT ENDODONT,LACKLAND AFB,TX 78236
[2] UNIV TEXAS,HLTH SCI CTR,SCH DENT,DEPT DENT DIAGNOST SCI,SAN ANTONIO,TX 78284
关键词
D O I
10.1016/S0099-2399(06)80441-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study used a modified Bramante technique and new digital subtraction software to compare root canals prepared by nickel-titanium (Ni-Ti) hand, Ni-Ti engine-driven, and stainless steel hand endodontic instruments. Sixty mesial canals of extracted human mandibular molars were randomly divided into five groups. The roots were embedded in clear resin and cross-sectioned in the apical and mid-root areas, In group A, canals were instrumented using a quarter turn/pull technique with K-Flex files. In group B, canals were prepared with Ni-Ti hand files (Mity files) using the same technique as in group A. Group C was prepared with NT Sensor engine-driven files. Group D canals were prepared with Ni-Ti Canal Master ''U'' hand instruments. Group E was prepared with engine-driven Ni-Ti Lightspeed instruments. Digitized images of the uninstrumented canals were compared with images of the instrumented canals. Engine-driven Ni-Ti instruments (Lightspeed and NT Sensor file) and hand instrumentation with the Canal Master ''U'' caused significantly less canal transportation (p < 0.05), remained more centered in the canal (p < 0.05), removed less dentin (p < 0.05), and produced rounder canal preparations than K-Flex and Mity files. Engine instrumentation with Lightspeed and NT Sensor file was significantly faster than hand instrumentation (p < 0.05).
引用
收藏
页码:146 / 151
页数:6
相关论文
共 19 条
[1]   A METHODOLOGY FOR EVALUATION OF ROOT-CANAL INSTRUMENTATION [J].
BRAMANTE, CM ;
BERBERT, A ;
BORGES, RP .
JOURNAL OF ENDODONTICS, 1987, 13 (05) :243-245
[2]   THE EFFECTS OF 4 INSTRUMENTATION TECHNIQUES ON ROOT-CANAL SHAPE [J].
CALHOUN, G ;
MONTGOMERY, S .
JOURNAL OF ENDODONTICS, 1988, 14 (06) :273-277
[3]   COMPARISON OF MECHANICAL AND STANDARD HAND INSTRUMENTATION TECHNIQUES IN CURVED ROOT CANALS [J].
CAMPOS, JM ;
DELRIO, C .
JOURNAL OF ENDODONTICS, 1990, 16 (05) :230-234
[4]  
DELRIO CE, 1991, SOPHOMORE PRECLINCIA, P47
[5]  
DOVE SB, 1988, COMPUTER AIDED RADIO
[6]   A COMPARISON OF THE CANAL MASTER ENDODONTIC INSTRUMENT AND K-TYPE FILES FOR ENLARGEMENT OF CURVED ROOT CANALS [J].
GILLES, JA ;
DELRIO, CE .
JOURNAL OF ENDODONTICS, 1990, 16 (12) :561-565
[7]   COMPARISON OF ROOT-CANAL PREPARATION USING DIFFERENT AUTOMATED DEVICES AND HAND INSTRUMENTATION [J].
HULSMANN, M ;
STRYGA, F .
JOURNAL OF ENDODONTICS, 1993, 19 (03) :141-145
[8]  
INGLE JI, 1985, ENDODONTICS
[9]   THE EFFECTS OF CANAL MASTER, FLEX-R, AND K-FLEX INSTRUMENTATION ON ROOT-CANAL CONFIGURATION [J].
LESEBERG, DA ;
MONTGOMERY, S .
JOURNAL OF ENDODONTICS, 1991, 17 (02) :59-65
[10]   TORSIONAL PROPERTIES OF THE CANAL MASTER INSTRUMENT [J].
MASSA, GR ;
NICHOLLS, JI ;
HARRINGTON, GW .
JOURNAL OF ENDODONTICS, 1992, 18 (05) :222-227