Objectives To determine whether a dual-camera markerless motion capture system can be used for lower limb kinematic evaluation in athletes in a preseason screening setting. Design Descriptive laboratory study. Setting Laboratory setting. Participants Thirty-four (n=34) healthy athletes. Main outcome measures Three dimensional lower limb kinematics during three functional tests: Single Leg Squat (SLS), Single Leg Jump, Modified Counter-movement Jump. The tests were simultaneously recorded using both a marker-based motion capture system and two Kinect v2 cameras using iPi Mocap Studio software. Results Excellent agreement between systems for the flexion/extension range of motion of the shin during all tests and for the thigh abduction/adduction during SLS were seen. For peak angles, results showed excellent agreement for knee flexion. Poor correlation was seen for the rotation movements. Conclusions This study supports the use of dual Kinect v2 configuration with the iPi software as a valid tool for assessment of sagittal and frontal plane hip and knee kinematic parameters but not axial rotation in athletes.
引用
收藏
页数:9
相关论文
共 30 条
[1]   Detection of gait cycles in treadmill walking using a Kinect [J].
Auvinet, Edouard ;
Multon, Franck ;
Aubin, Carl-Eric ;
Meunier, Jean ;
Raison, Maxime .
GAIT & POSTURE, 2015, 41 (02) :722-725
[2]   Smallest real difference, a link between reproducibility and responsiveness [J].
Beckerman, H ;
Roebroeck, ME ;
Lankhorst, GJ ;
Becher, JG ;
Bezemer, PD ;
Verbeek, ALM .
QUALITY OF LIFE RESEARCH, 2001, 10 (07) :571-578
[3]   Using perceptive computing in multiple sclerosis the Short Maximum Speed Walk test [J].
Behrens, Janina ;
Pfueller, Caspar ;
Mansow-Model, Sebastian ;
Otte, Karen ;
Paul, Friedemann ;
Brandt, Alexander U. .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2014, 11
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Validity and reliability of the Kinect within functional assessment activities: Comparison with standard stereophotogrammetry [J].
Bonnechere, B. ;
Jansen, B. ;
Salvia, P. ;
Bouzahouene, H. ;
Omelina, L. ;
Moiseev, F. ;
Sholukha, V. ;
Cornelis, J. ;
Rooze, M. ;
Jan, S. Van Sint .
GAIT & POSTURE, 2014, 39 (01) :593-598
[6]   Reliability and concurrent validity of the Microsoft Xbox One Kinect for assessment of standing balance and postural control [J].
Clark, Ross A. ;
Pua, Yong-Hao ;
Oliveira, Cristino C. ;
Bower, Kelly J. ;
Thilarajah, Shamala ;
McGaw, Rebekah ;
Hasanki, Ksaniel ;
Mentiplay, Benjamin F. .
GAIT & POSTURE, 2015, 42 (02) :210-213
[7]   Concurrent validity of the Microsoft Kinect for Windows v2 for measuring spatiotemporal gait parameters [J].
Dolatabadi, Elham ;
Taati, Babak ;
Mihailidis, Alex .
MEDICAL ENGINEERING & PHYSICS, 2016, 38 (09) :952-958
[8]   Improved kinect-based spatiotemporal and kinematic treadmill gait assessment [J].
Eltoukhy, Moataz ;
Oh, Jeonghoon ;
Kuenze, Christopher ;
Signorile, Joseph .
GAIT & POSTURE, 2017, 51 :77-83
[9]   Validation of the Microsoft Kinect® camera system for measurement of lower extremity jump landing and squatting kinematics [J].
Eltoukhy, Moataz ;
Kelly, Adam ;
Kim, Chang-Young ;
Jun, Hyung-Pil ;
Campbell, Richard ;
Kuenze, Christopher .
SPORTS BIOMECHANICS, 2016, 15 (01) :89-102
[10]  
Fleiss J, 1986, ANAL CLIN EXP, V1st, DOI [10.1002/9781118032923.ch1, DOI 10.1002/9781118032923.CH1, DOI 10.1002/9781118032923]