EVALUATION OF MITRAL-STENOSIS WITH VELOCITY-ENCODED CINE-MAGNETIC RESONANCE IMAGING

被引:32
作者
HEIDENREICH, PA
STEFFENS, J
FUJITA, N
OSULLIVAN, M
CAPUTO, GR
FOSTER, E
HIGGINS, CB
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT RADIOL,MRI SECT,SAN FRANCISCO,CA 94142
[2] UNIV CALIF SAN FRANCISCO,DIV CARDIOL,SAN FRANCISCO,CA 94142
关键词
D O I
10.1016/S0002-9149(99)80555-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Velocity-encoded cine-magnetic resonance imaging (VEC-MRI) is a new method for quantitation of blood flow with the potential to measure high-velocity jets across stenotic valves. The objective of this study was to evaluate the ability of VEC-MRI to measure transmitral velocity in patients with mitral stenosis. Sixteen patients with known mitral stenosis were studied. A 1.5 Tesla superconducting magnet was used to obtain velocity-encoded images in the left ventricular short-axis plane. Images were obtained throughout the cardiac cycle at 3 consecutive slices beginning proximal to the mitral coaptation point. To determine the optimal slice thickness for MRI imaging, both 10 mm and 5 mm thicknesses were used. Echocardiography including continuous-wave Doppler was performed on every patient within 2 hours of MRI imaging. Peak velocity was determined for both VEC-MRI and Doppler-echo images. Two observers independently measured the VEC-MRI mitral inflow velocities. Of the 16 patients, imaged data were incomplete in only 1 study, and all images were adequate for analysis. Strong correlations were found for measurements of mitral valve gradient for both 10 mm (peak r = 0.89, mean r = 0.84) and 5 mm (peak r = 0.82, mean r = 0.95) slice thicknesses. Measurements of peak velocity with VEC-MRI (10 mm) agreed well with Doppler: mean 1.46 m/s, mean of differences (Doppler MRI) 0.38 m/s, standard deviation of differences 0.2 m/s. These findings suggest that VEC-MRI can noninvasively determine the severity of mitral stenosis.
引用
收藏
页码:365 / 369
页数:5
相关论文
共 18 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
CRANNEY GB, 1991, CIRCULATION, P1216
[3]  
DIJK PV, 1984, J COMPUT ASSIST TOMO, V8, P429
[4]   VELOCITY-ENCODED CINE MRI IN THE EVALUATION OF LEFT-VENTRICULAR DIASTOLIC FUNCTION - MEASUREMENT OF MITRAL-VALVE AND PULMONARY VEIN FLOW VELOCITIES AND FLOW VOLUME ACROSS THE MITRAL-VALVE [J].
HARTIALA, JJ ;
MOSTBECK, GH ;
FOSTER, E ;
FUJITA, N ;
DULCE, MC ;
CHAZOUILLERES, AF ;
HIGGINS, CB .
AMERICAN HEART JOURNAL, 1993, 125 (04) :1054-1066
[5]   FUNCTIONAL-EVALUATION OF THE HEART WITH MAGNETIC-RESONANCE IMAGING [J].
HIGGINS, CB ;
HOLT, W ;
PFLUGFELDER, P ;
SECHTEM, U .
MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (02) :121-139
[6]  
HIGGINS CB, 1991, CIRCULATION, P1198
[7]   MAGNETIC-RESONANCE JET VELOCITY MAPPING IN MITRAL AND AORTIC-VALVE STENOSIS [J].
KILNER, PJ ;
MANZARA, CC ;
MOHIADDIN, RH ;
PENNELL, DJ ;
SUTTON, MGS ;
FIRMIN, DN ;
UNDERWOOD, SR ;
LONGMORE, DB .
CIRCULATION, 1993, 87 (04) :1239-1248
[8]   VALVE AND GREAT VESSEL STENOSIS - ASSESSMENT WITH MR JET VELOCITY MAPPING [J].
KILNER, PJ ;
FIRMIN, DN ;
REES, RSO ;
MARTINEZ, J ;
PENNELL, DJ ;
MOHIADDIN, RH ;
UNDERWOOD, SR ;
LONGMORE, DB .
RADIOLOGY, 1991, 178 (01) :229-235
[9]   RIGHT AND LEFT-VENTRICULAR STROKE VOLUME MEASUREMENTS WITH VELOCITY-ENCODED CINE MR IMAGING - INVITRO AND INVIVO VALIDATION [J].
KONDO, C ;
CAPUTO, GR ;
SEMELKA, R ;
FOSTER, E ;
SHIMAKAWA, A ;
HIGGINS, CB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (01) :9-16
[10]   LOW-FIELD CINE MAGNETIC-RESONANCE IMAGING IN AORTIC-VALVE DISEASE [J].
METCALFE, MJ ;
JONES, RA ;
REDPATH, TW ;
SMITH, FW ;
JENNINGS, K ;
WALTON, S .
BRITISH JOURNAL OF RADIOLOGY, 1989, 62 (744) :1063-1066