FUSION-REACTOR DESIGN PARAMETERS RELEVANT TO THE PASSIVE REMOVAL OF DECAY HEAT

被引:0
作者
ANDRITSOS, F
机构
关键词
D O I
10.1016/0920-3796(95)80022-P
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The bulk quantity of decay heat produced by the activated structural materials of fusion reactors is a matter of concern. Tn adiabatic conditions it has the potential to cause at least a partial meltdown of the reactor. Although a fusion reactor, even in conditions of total loss of coolant accident (LOCA), is not adiabatic, it will be an extremely well-insulated thermal system. Extensive studies have been performed in the frame of the ITER/CDA, DEMO, SEAFP and ITER/EDA programmes with the scope of predicting the post-accident temperature transient for the ''envelope'' conditions of instantaneous, total and permanent loss of every form of active cooling of the reactor. These studies included numerical calculation of the neutron fluxes and decay heat histories and consequently the simulation of the ''envelope'' post-accident temperature transient of the whole tokamak for as long as 3 months after the accident. A variety of design configurations, including various structural materials, breeding and shielding blankets, etc., have been simulated. The results from these studies indicated that in most cases, even under ''envelope'' LOCA conditions, the structural integrity of the containment would not be compromised. It also became apparent that, even in cases where the resulting temperatures were too high, slight design modifications in the regions outside the vacuum vessel were sufficient to significantly lower the post-accident temperature peaks. All these studies and analysis being done a posteriori to the design, any modifications, even if not relevant to the first wall, blanket or vacuum vessel, are not easily accepted. The present paper responds to the need for integrating the considerations on decay heat generation and passive dissipation into the design activity by identifying the factors that affect the post-accident transient temperatures and providing some general design guidelines.
引用
收藏
页码:188 / 192
页数:5
相关论文
共 13 条
[1]   AFTERHEAT IN FUSION STRUCTURAL-MATERIALS AND THERMAL TRANSIENT SCENARIOS IN ITER [J].
ANDRITSOS, F ;
ZUCCHETTI, M .
FUSION ENGINEERING AND DESIGN, 1991, 17 :409-414
[2]   AFTERHEAT TRANSIENT IN ITER AFTER A TOTAL LOSS OF COOLANT ACCIDENT [J].
ANDRITSOS, F ;
ZUCCHETTI, M .
FUSION ENGINEERING AND DESIGN, 1991, 15 (02) :113-119
[3]  
ANDRITSOS F, IN PRESS SEAFP POST
[4]  
ANDRITSOS F, 1995, FUSION ENG DESIGN, V29
[5]  
ANDRITSOS F, 1992, TNI9281 CEC JRC ISPR
[6]  
ANDRITSOS F, IN PRESS J NUCL MATE
[7]  
ANDRITSOS F, IN PRESS ANS T
[8]  
ANDRITSOS F, 1990, 16TH P S FUS TECHN L, P1477
[9]  
KONRAD C, 1992, 17TH P SOFT ROM, P1734
[10]  
RAEDER J, 1988, NET88IN044 INT NOT