Vertebral and Basilar Arteries: Transcranial Color-Coded Duplex Ultrasonography versus Conventional TCD in Detection of Narrowings

被引:6
作者
Arkuszewski, M. [1 ,2 ]
Swiat, M. [1 ,2 ]
Hurst, R. W. [1 ]
Weigele, J. B. [1 ]
Al-Okaili, R. N. [1 ]
Kasner, S. E. [3 ]
Melhem, E. R. [1 ]
Krejza, J. [1 ,4 ,5 ]
机构
[1] Univ Penn, Dept Radiol, Div Neuroradiol, Philadelphia, PA 19104 USA
[2] Med Univ Silesia, Dept Neurol, Katowice, Poland
[3] Hosp Univ Penn, Dept Neurol, Philadelphia, PA USA
[4] Med Univ Gdansk, Dept Nucl Med, Gdansk, Poland
[5] Al Imam Muhammad Ibn Saud Islam Univ, Riyadh, Saudi Arabia
关键词
basilar artery; vertebral artery; ultrasonography; transcranial doppler; transcranial color-coded doppler sonography;
D O I
10.1177/197140091202500502
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
We prospectively compared the accuracies of conventional transcranial Doppler ultrasound (TCD) and transcranial color-coded duplex sonography (TCCS) in the diagnosis of narrowing of the basilar(BA) and vertebral arteries (VA). Fifty-six consecutive patients (mean age 55.8 years; 34 women) after subarachnoid hemorrhage (n=46), stroke or transient ischemic attack (n=5), and for other reasons (n=5) underwent on the same day TCD, TCCS and the intra- arterial digital subtraction angiography (DSA) - the reference standard. The accuracy of peak-systolic (V-PS), mean (V-M), and end-diastolic velocities (V-ED) in detection of any arterial narrowing was estimated using the receiver operator characteristic (ROC) curve methodology and the total area (A(z)) under the curve. Accuracy of TCCS in detection of VA narrowing based on V-PS and V-M measurements was significantly higher than accuracy of TCD (A(z)=0.65 for V-PS and A(z) =0.62 for V-M versus A (z) =0.51 and A (z) =0.50, respectively, p<0.05 for both). Accuracy of TCCS in detection of BA narrowing was also higher than accuracy of TCD based on V PS measurements (A (z) = 0.69 versus A (z) = 0.50, respectively), with a trend toward significant difference, p=0.085. The accuracy of TCCS is superior to accuracy of TCD in detection of narrowings of vertebral and basilar arteries, thus TCCS should be preferred in routine clinical practice.
引用
收藏
页码:509 / 514
页数:6
相关论文
共 20 条
[1]  
Aaslid R., 1983, TRANSCRANIAL DOPPLER, P36
[2]   Assessment of ≥50% and &lt;50% intracranial stenoses by transcranial color-coded duplex sonography [J].
Baumgartner, RW ;
Mattle, HP ;
Schroth, G .
STROKE, 1999, 30 (01) :87-92
[3]   Screening for intracranial stenosis with transcranial Doppler: The accuracy of mean flow velocity thresholds [J].
Felberg, RA ;
Christou, L ;
Demchuk, AM ;
Malkoff, M ;
Alexandrov, AV .
JOURNAL OF NEUROIMAGING, 2002, 12 (01) :9-14
[4]  
FORTEZA AM, 2003, IMAGING CEREBROVASCU, P3
[5]   A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1983, 148 (03) :839-843
[6]   Angle-corrected imaging transcranial doppler sonography versus imaging and nonimaging transcranial doppler sonography in children with sickle cell disease [J].
Krejza, J. ;
Rudzinski, W. ;
Pawlak, M. A. ;
Tonnaszewski, M. ;
Ichord, R. ;
Kwiatkowski, J. ;
Gor, D. ;
Melhem, E. R. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (08) :1613-1618
[7]   Middle cerebral artery spasm after subarachnoid hemorrhage: Detection with transcranial color-coded duplex US [J].
Krejza, J ;
Kochanowicz, J ;
Mariak, Z ;
Lewko, J ;
Melhem, ER .
RADIOLOGY, 2005, 236 (02) :621-629
[8]   A guide to the identification of major cerebral arteries with transcranial color Doppler sonography [J].
Krejza, J ;
Mariak, Z ;
Melhem, ER ;
Bert, RJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (05) :1297-1303
[9]  
Krejza J, 2001, AM J NEURORADIOL, V22, P1743