PRECISE AREA DETERMINATION OF SKIN-PRICK TESTS - VALIDATION OF A SCANNING DEVICE AND SOFTWARE FOR A PERSONAL-COMPUTER

被引:63
作者
POULSEN, LK
LIISBERG, C
BINDSLEVJENSEN, C
MALLING, HJ
机构
[1] Laboratory of Medical Allergology, Medical Department TTA 7542, National University Hospital, DK-2200 Copenhagen N
关键词
D O I
10.1111/j.1365-2222.1993.tb02485.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
When skin-prick tests (SPTs) are used quantitatively, the circumference of the weal and/or the flare is outlined using a felt tip pen, and transferred to paper by adhesive tape. The aim of the study was to develop and validate a procedure, objectively and precisely determining these areas after transfer to paper. A system was developed enabling the drawing of the area of weal or flare to be read by a hand-held scanner and calculated on a personal computer. Areas in the 5-500 mm2 range could be determined with day-to-day and interoperator coefficients of variation (CVs) of 3.1% and 1.8%, respectively. Accuracy was determined in two ways: by correlation to cutting/weighing of four times enlarged SPT areas (r2 = 0.999, P < 0.001) and by measuring standardized areas (deviations less than intra-assay CV, i.e. 1-2%). For comparison, CVs of alternative methods were also determined: eight different areas (9-76 mm2) were evaluated in quadruplicate using the SPT-scanner (CV = 1.4%), by cutting/weighing of paper (CV = 2.3%), by digitizing (CV = 4.4%) or by measuring longest and orthogonal diameters (CV = 13.6%). In conclusion, the scanning device and software provides an, objective and reproducible procedure for rapid determination of SPT areas. When areas are determined by scanning, digitizing or cutting/weighing the variations in area determination becomes negligible compared to the variations of the entire skin test procedure.
引用
收藏
页码:61 / 68
页数:8
相关论文
共 18 条
[1]   A COMPARISON OF 6 EPICUTANEOUS DEVICES IN THE PERFORMANCE OF IMMEDIATE HYPERSENSITIVITY SKIN TESTING [J].
ADINOFF, AD ;
ROSLONIEC, DM ;
MCCALL, LL ;
NELSON, HS .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1989, 84 (02) :168-174
[2]   DOUBLE-BLIND, PLACEBO-CONTROLLED IMMUNOTHERAPY WITH MIXED GRASS-POLLEN ALLERGOIDS .2. COMPARISON BETWEEN PARAMETERS ASSESSING THE EFFICACY OF IMMUNOTHERAPY [J].
BOUSQUET, J ;
MAASCH, H ;
MARTINOT, B ;
HEJJAOUI, A ;
WAHL, R ;
MICHEL, FB .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1988, 82 (03) :439-446
[3]  
Dreborg S, 1989, ALLERGY S, V44, P22
[4]  
DREBORG S, 1987, THESIS LINKOPING U M
[5]   REPRODUCIBILITY OF SKIN PRICK TESTING WITH ALLERGEN EXTRACTS FROM DIFFERENT MANUFACTURERS [J].
EICHLER, I ;
GOTZ, M ;
JARISCH, R ;
EICHLER, HG ;
MOSS, R .
ALLERGY, 1988, 43 (06) :458-463
[6]   DIAGNOSIS AND IMMUNOTHERAPY OF MOLD ALLERGY .2. REPRODUCIBILITY AND RELATIONSHIP BETWEEN SKIN SENSITIVITY ESTIMATED BY ENDPOINT TITRATION AND HISTAMINE EQUIVALENT REACTION USING SKIN PRICK TEST AND INTRADERMAL TEST [J].
MALLING, HJ .
ALLERGY, 1985, 40 (05) :354-362
[7]   THE ALLERGY PRICKER - QUALITATIVE ASPECTS OF SKIN PRICK TESTING USING A PRECISION NEEDLE [J].
MALLING, HJ ;
ANDERSEN, CE ;
BOAS, B ;
HOLGERSEN, F ;
MUNCH, EP ;
WEEKE, B .
ALLERGY, 1982, 37 (08) :563-567
[8]   REPRODUCIBILITY OF SKIN SENSITIVITY USING A QUANTITATIVE SKIN PRICK TEST [J].
MALLING, HJ .
ALLERGY, 1985, 40 (06) :400-404
[9]   SKIN PRICK TESTING AND THE USE OF HISTAMINE REFERENCES [J].
MALLING, HJ .
ALLERGY, 1984, 39 (08) :596-601
[10]   SKIN REACTIVITY TO CODEINE AND HISTAMINE DURING PROLONGED CORTICOSTEROID-THERAPY [J].
OLSON, R ;
KARPINK, MH ;
SHELANSKI, S ;
ATKINS, PC ;
ZWEIMAN, B .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1990, 86 (02) :153-159