UPWARD DISPLACEMENT OF THE CENTER OF GRAVITY IN PARAPLEGIC PATIENTS

被引:7
作者
DUVALBEAUPERE, G
ROBAIN, G
机构
[1] Chef de clinique, INSERM U215, Clinique de Réeducation motrice (Pr.Held), Hôpital R.Poincaré, Garches
来源
PARAPLEGIA | 1991年 / 29卷 / 05期
关键词
SPINAL CORD PATIENTS; CENTER OF GRAVITY; WHEELCHAIR STABILITY; SITTING-POSITION;
D O I
10.1038/sc.1991.45
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The centres of gravity of 44 complete chronic spinal cord injured patients and 24 normal subjects were measured using a gamma ray scanner (Barycentremetre). The results are expressed as a percentage of body length and as anatomical level. The mean weight of paraplegic patients was 12kg less than the controls. The centre of gravity was 5% of body length higher in the paraplegic patients than in the controls, equivalent to 3 to 4 vertebrae level. The importance of such changes in the centre of gravity for the design of stable wheelchairs is discussed.
引用
收藏
页码:309 / 317
页数:9
相关论文
共 9 条
[1]  
Contini R., Body segment parameters, Artificial Limbs, 16, pp. 1-19, (1972)
[2]  
Cosson P., Desmoineaux P., Robain G., Duval-Beaupere G., Valeurs inertielles des segments corporels supportes par les vertebres, Journal of Biophysics and Biomechanics, 11, pp. 52-53, (1987)
[3]  
Cosson P., Evaluation personnalisee des efforts exercees sur les etages vertebraux dorsaux et lombaires de l’homme en position debout et assise, Memoire Pour Ie DEA De Biomechanique Et De Physiologie Du Mouvement. Universite De Paris, (1987)
[4]  
Maricourt D.D., La position assise along terme chez le paralegique, Memoire De DEA De Sciences Et Techniques Appliquees Aux Handicaps, (1986)
[5]  
Duval-Beaupere G., Ovazza D., Tisseau J., Pascal A., Roche P., Csakvary E., Mise au point d’un appareillage de mesure de la masse de segments corporels et de son point d’application, INSERM, Colloque De Synthese d’action Thematique n°6, pp. 165-177, (1976)
[6]  
Duval-Beaupere G., Robain G., Visualization on full spine radiographs of the anatomical connections of the centres of the segmental body mass supported by each vertebra and measured in vivo, International Orthopaedics, 11, pp. 261-269, (1987)
[7]  
Duval-Beaupere G., Lougovoy J., Trocellier L., Lacert P.H., Trunk and leg growth in children with paraplegia caused by spinal cord injury, Paraplegia, 21, pp. 339-350, (1983)
[8]  
Pascal A., Csakvary E., Porte P., Barycentremetre MCGlO, Notice technique, CEA SES/PUP/ SERF, pp. 74-720, (1974)
[9]  
Santchi W.R., Dubois J., Omoto C., Moments of inertia and centres of gravity of the living human body. Technical documentary report NO-TDR-63-36, Wright-Patterson Air Force Base Ohio, pp. 1-60, (1963)