EVALUATION OR THE PERFORMANCE OF A MICROFLOW RATE LC/MS PARTICLE-BEAM INTERFACE

被引:29
作者
CAPPIELLO, A
FAMIGLINI, G
机构
[1] Istituto di Scienze Chimiche, Università di Urbino, 61029 Urbino
关键词
D O I
10.1021/ac00094a019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A modified Hewlett-Packard LC/MS particle beam interface which allows the use of mobile phase microflow rates (down to 1 mu L/min) has been refined and evaluated. Its overall performance was accurately investigated to discover and underline positive contributions to liquid chromatography/mass spectrometry interfacing. Several aspects of the coupling technique, including the optimization procedure, temperature influence, and flow rate variation, were considered; the results were compared to those obtained with a standard Hewlett-Packard interface. Detection limits and the use of nonvolatile buffers were also evaluated. The new interface gave positive results in most of the tests performed, and it was demonstrated that it satisfies both chromatographic and mass spectrometric crucial requirements.
引用
收藏
页码:3970 / 3976
页数:7
相关论文
共 14 条
[1]   PARTICLE BEAM LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY ON A DOUBLE-FOCUSING SECTOR INSTRUMENT [J].
BACZYNSKYJ, L .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 562 (1-2) :13-29
[2]   INVESTIGATION OF ENHANCED ION ABUNDANCES FROM A CARRIER PROCESS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY PARTICLE BEAM MASS-SPECTROMETRY [J].
BELLAR, TA ;
BEHYMER, TD ;
BUDDE, WL .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1990, 1 (01) :92-98
[3]   NEW MATERIALS AND PACKING TECHNIQUES FOR MICRO-HPLC PACKED CAPILLARY COLUMNS [J].
CAPPIELLO, A ;
PALMA, P ;
MANGANI, F .
CHROMATOGRAPHIA, 1991, 32 (7-8) :389-391
[4]   MICRO FLOW-RATE PARTICLE BEAM INTERFACE FOR CAPILLARY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
CAPPIELLO, A ;
BRUNER, F .
ANALYTICAL CHEMISTRY, 1993, 65 (09) :1281-1287
[5]   DETERMINATION OF ACIDIC AND BASIC NEUTRAL PESTICIDES IN WATER WITH A NEW MICROLITER FLOW-RATE LC/MS PARTICLE-BEAM INTERFACE [J].
CAPPIELLO, A ;
FAMIGLINI, G ;
BRUNER, F .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :1416-1423
[6]  
CAPPIELLO A, 1993, 41ST ASMS C SAN FRAN
[7]   LIQUID-CHROMATOGRAPHY CAPILLARY COLUMNS DRY-PACKED WITH POLAR AND NONPOLAR STATIONARY PHASES [J].
CRESCENTINI, G ;
MASTROGIACOMO, AR .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1991, 3 (06) :539-545
[8]   PREPARATION AND EVALUATION OF DRY-PACKED CAPILLARY COLUMNS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CRESCENTINI, G ;
BRUNER, F ;
MANGANI, F ;
GUAN, YF .
ANALYTICAL CHEMISTRY, 1988, 60 (17) :1659-1662
[9]   MASS-TRANSPORT AND CALIBRATION IN LIQUID-CHROMATOGRAPHY PARTICLE BEAM MASS-SPECTROMETRY [J].
HO, JS ;
BEHYMER, TD ;
BUDDE, WL ;
BELLAR, TA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (06) :662-671
[10]   PARTICLE BEAM INTERFACE FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
LIGON, WV ;
DORN, SB .