Simultaneous Determination of Five Porphyrins in Human Urine and Plasma Using High Performance Liquid Chromatography-Tandem Mass Spectrometry

被引:2
作者
Hur, Yeoun [1 ,2 ]
Tae, Sookil [1 ,7 ]
Koh, Yun-Joo [3 ,4 ]
Hong, Sung-Hyun [5 ]
Yoon, Young Ho [5 ]
Jang, Haejong [1 ,6 ]
Kim, Sooji [1 ,6 ]
Kim, Kyeong Ho [6 ]
Kang, Seung Woo [1 ,6 ]
Lee, Youngshin [1 ]
Han, Sang Beom [2 ]
机构
[1] Int Sci Stand Co Ltd, Dept Analyt Res Serv, Chunchon 200161, South Korea
[2] Chung Ang Univ, Coll Pharm, Dept Pharmaceut Anal, 84 Heukseok Ro, Seoul 156756, South Korea
[3] Korea Inst Childrens Social Dev, Seoul 122824, South Korea
[4] Rudolph Child Res Ctr, Seoul 122824, South Korea
[5] EONE Labs, Metabol Res Ctr Inst, Incheon 406840, South Korea
[6] Kangwon Natl Univ, Dept Pharm, Coll Pharm, Chunchon 200701, South Korea
[7] Pohang Univ Sci & Technol, Dept Life Sci, Pohang 790784, South Korea
关键词
Porphyrins; tandem mass spectrometry; autism; diagnosis; plasma; urine;
D O I
10.5478/MSL.2014.5.2.42
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESIMS/MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphyrin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column (150 mm x 2.0 mm, 4 mu m) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/v) at a flow rate of 450 mu L/min. Porphyrins and the internal standard (IS), coproporphyrin I-N-15(4), were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensitivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recovery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.
引用
收藏
页码:42 / 48
页数:7
相关论文
共 26 条
  • [11] Fateen E., 2005, EGYPT J HUM GENET, V61, P267
  • [12] DETERMINATION OF INDIVIDUAL PORPHYRINS IN RODENT URINE USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOLLOWING CLEANUP BY ANION-EXCHANGE CHROMATOGRAPHY
    HAHN, ME
    GASIEWICZ, TA
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 563 (02): : 363 - 368
  • [13] HENDERSON MJ, 1989, CLIN CHEM, V35, P1043
  • [14] Disordered Porphyrin Metabolism: A Potential Biological Marker for Autism Risk Assessment
    Heyer, Nicholas J.
    Echeverria, Diana
    Woods, James S.
    [J]. AUTISM RESEARCH, 2012, 5 (02) : 84 - 92
  • [15] Hindmarsh JT, 1999, CLIN CHEM, V45, P1070
  • [16] ISOCRATIC ION-PAIR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHODS FOR THE DETERMINATION OF UROPORPHYRIN AND COPROPORPHYRIN TYPE-II AND TYPE-IV ISOMERS IN HUMAN-URINE
    JACOB, K
    EGELER, E
    NEUMEIER, D
    KNEDEL, M
    [J]. JOURNAL OF CHROMATOGRAPHY, 1989, 468 : 329 - 338
  • [17] URINARY PORPHYRIN PROFILES BY LASER-DESORPTION IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETRY WITHOUT THE USE OF CLASSICAL MATRICES
    JONES, RM
    LAMB, JH
    LIM, CK
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (10) : 921 - 923
  • [18] Prevalence of Autism Spectrum Disorders in a Total Population Sample
    Kim, Young Shin
    Leventhal, Bennett L.
    Koh, Yun-Joo
    Fombonne, Eric
    Laska, Eugene
    Lim, Eun-Chung
    Cheon, Keun-Ah
    Kim, Soo-jeong
    Kim, Young-Key
    Lee, HyunKyung
    Song, Dong-Ho
    Grinker, Roy Richard
    [J]. AMERICAN JOURNAL OF PSYCHIATRY, 2011, 168 (09) : 904 - 912
  • [20] ANALYSIS OF URINARY PORPHYRINS BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY-ELECTROSPRAY IONIZATION MASS SPECTROMETRY
    Li, Jinhua
    Cai, Zongwei
    Xu, Shoufang
    Liao, Chunyang
    Song, Xingliang
    Chen, Lingxin
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (15) : 1578 - 1593