DETECTOR NONLINEARITY IN FREQUENCY-DOMAIN FLUOROMETRY

被引:4
|
作者
WIRTH, MJ
BURBAGE, JD
ZULLI, SL
机构
关键词
D O I
10.1364/AO.32.000976
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Frequency-domain fluorometry relies on the measurement of the phase and amplitudes of the Fourier components of the time-dependent fluorescence signal. Experimental results that show that a conventional photomultiplier is subject to intensity-dependent phase shifts are presented. The measurements indicate that this is a problem well below the maximum linear current of the photomultiplier response. These results have important implications in frequency-domain fluorescence anisotropy experiments, in which the parallel and the perpendicular components of the emission intensity are inherently different from one another: a phase shift can be introduced by the photomultiphlier.
引用
收藏
页码:976 / 980
页数:5
相关论文
共 50 条
  • [1] Frequency-domain fluorometry.
    Nakaema, MKK
    Sanches, R
    QUIMICA NOVA, 1999, 22 (03): : 412 - 416
  • [2] Background suppression in frequency-domain fluorometry
    Lakowicz, JR
    Gryczynski, I
    Gryczynski, Z
    Johnson, ML
    ANALYTICAL BIOCHEMISTRY, 2000, 277 (01) : 74 - 85
  • [3] RECENT DEVELOPMENTS IN FREQUENCY-DOMAIN FLUOROMETRY
    LAKOWICZ, JR
    MALIWAL, BP
    GRATTON, E
    ANALYTICAL INSTRUMENTATION, 1985, 14 (3-4): : 193 - 223
  • [4] CORRECTION FOR CONTAMINANT FLUORESCENCE IN FREQUENCY-DOMAIN FLUOROMETRY
    LAKOWICZ, JR
    JAYAWEERA, R
    JOSHI, N
    GRYCZYNSKI, I
    ANALYTICAL BIOCHEMISTRY, 1987, 160 (02) : 471 - 479
  • [5] SYNTHESIZERS PHASE NOISE IN FREQUENCY-DOMAIN FLUOROMETRY
    BARBIERI, B
    DEPICCOLI, F
    GRATTON, E
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (10): : 3201 - 3206
  • [6] SUBTRACTION OF BACKGROUND FLUORESCENCE IN MULTIHARMONIC FREQUENCY-DOMAIN FLUOROMETRY
    PERIASAMY, N
    VERKMAN, AS
    ANALYTICAL BIOCHEMISTRY, 1992, 201 (01) : 107 - 113
  • [7] A METHOD FOR ONLINE BACKGROUND SUBTRACTION IN FREQUENCY-DOMAIN FLUOROMETRY
    REINHART, GD
    FEDDERSEN, B
    JAMESON, DM
    GRATTON, E
    BIOPHYSICAL JOURNAL, 1990, 57 (02) : A189 - A189
  • [8] CORRECTION OF SYSTEMATIC PHASE ERRORS IN FREQUENCY-DOMAIN FLUOROMETRY
    POUGET, J
    MUGNIER, J
    VALEUR, B
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1989, 22 (10): : 855 - 862
  • [9] DEMONSTRATION OF AN ASSOCIATED ANISOTROPY DECAY BY FREQUENCY-DOMAIN FLUOROMETRY
    SZMACINSKI, H
    JAYAWEERA, R
    CHEREK, H
    LAKOWICZ, JR
    BIOPHYSICAL CHEMISTRY, 1987, 27 (03) : 233 - 241
  • [10] DISTRIBUTION OF DISTANCES IN MACROMOLECULES FROM FREQUENCY-DOMAIN FLUOROMETRY
    LAKOWICZ, JR
    MALIWAL, B
    KEATING, S
    BIOPHYSICAL JOURNAL, 1985, 47 (02) : A210 - A210