TROCHANTERIC FIXATION BY CABLE GRIP IN HIP-REPLACEMENT

被引:50
作者
RITTER, MA
EIZEMBER, LE
KEATING, EM
FARIS, PM
机构
[1] LOUISIANA STATE UNIV,MED CTR,DEPT ORTHOPAED SURG,SHREVEPORT,LA 71105
[2] CTR HIP & KNEE SURG,MOORESVILLE,IN
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1991年 / 73卷 / 04期
关键词
D O I
10.1302/0301-620X.73B4.2071639
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We used the stainless steel cable grip system described by Dall and Miles in 1983 to fix trochanters in 40 hips after total arthroplasty with trochanteric osteotomy. The cable broke in 32.5% of the hips; the trochanter failed to unite in 37.5%. Significantly more cables broke when placed inside the femoral canal than when the cable was placed round the femoral shaft (58% as against 9.5%, difference p < 0.01). The high incidence of breakage may have resulted from contact between the stainless steel cable and the titanium prosthesis, from the acute angulation, or because of the lower fatigue strength of stainless steel. Better results have been obtained using cables with a higher fatigue strength, passed outside the proximal femur.
引用
收藏
页码:580 / 581
页数:2
相关论文
共 4 条
  • [1] CLARKE PR, 1979, CLIN ORTHOPAEDICS, V141, P102
  • [2] RE-ATTACHMENT OF THE GREATER TROCHANTER - THE USE OF THE TROCHANTER CABLE-GRIP SYSTEM
    DALL, DM
    MILES, AW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1983, 65 (01): : 55 - 59
  • [3] RITTER MA, 1981, CLIN ORTHOP RELAT R, V159, P177
  • [4] SCHUTZER SF, 1988, CLIN ORTHOP RELAT R, P172