HIGH-RESOLUTION Y-AXIS READOUT FOR DELAY-LINE MICROCHANNEL ANODES

被引:5
|
作者
RAFFANTI, R [1 ]
LAMPTON, M [1 ]
机构
[1] UNIV CALIF BERKELEY,SPACE SCI LAB,BERKELEY,CA 94720
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1993年 / 64卷 / 06期
关键词
D O I
10.1063/1.1144071
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have devised a method to obtain a high-resolution Y-axis event position determination from microchannel plate delay-line detectors. The method is based on the double-delay-line wedge-wedge charge partition principle of Lampton et al. [M. Lampton, 0. H. W. Siegmund, and R. Raffanti, IEEE Trans. Nucl. Sci. 37, 1548 (1990)], where the X axis is read out by a pair of side-by-side delay lines and the Y-axis coordinate is determined by comparing the charges on the two parallel delay lines. However, our new method abandons the common field return path of the two delay lines, and splits them into two adjacent but independent transformer coupled timing circuits having no common ground connection except via the charge-measurement amplifiers. Thus we eliminate the large electrostatic capacitance of the delay lines from the input of the charge-measuring system. Due to the very low output return capacitance of the split delay lines, the Y-axis noise performance is improved enormously. Over its limited working field, the spatial resolution in the Y coordinate can easily equal the resolution provided in the X coordinate by the delay line. Applications to extreme and far ultraviolet photon-counting spectroscopy are envisioned.
引用
收藏
页码:1506 / 1509
页数:4
相关论文
共 50 条
  • [1] A HIGH-RESOLUTION DELAY-LINE READOUT FOR MICROCHANNEL PLATES
    SIEGMUND, OHW
    LAMPTON, ML
    RAFFANTI, R
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY AND ATOMIC PHYSICS, 1989, 1159 : 476 - 485
  • [2] HIGH-RESOLUTION DELAY-LINE READOUTS FOR MICROCHANNEL PLATES
    SIEGMUND, OHW
    LAMPTON, M
    RAFFANTI, R
    HERRICK, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2): : 311 - 316
  • [3] DELAY-LINE READOUT OF MICROCHANNEL PLATES
    SOBOTTKA, SE
    WILLIAMS, MB
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 348 - 351
  • [4] DELAY-LINE ANODES FOR MICROCHANNEL-PLATE SPECTROMETERS
    LAMPTON, M
    SIEGMUND, O
    RAFFANTI, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1987, 58 (12): : 2298 - 2305
  • [5] HIGH-RESOLUTION READOUT OF MULTIWIRE PROPORTIONAL COUNTERS USING CATHODE COUPLED DELAY-LINE TECHNIQUE
    LACY, JL
    LINDSEY, RS
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1973, 18 (04): : 562 - 563
  • [6] HIGH-RESOLUTION DELAY-LINE READOUTS FOR ASTRONOMICAL SPECTROSCOPY
    SIEGMUND, OHW
    RAFFANTI, R
    STOCK, J
    HERRICK, W
    LAMPTON, M
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1992, (121): : 123 - 130
  • [7] Optimization of the readout electronics for microchannel plate delay line anodes
    Vallerga, J
    McPhate, J
    INSTRUMENTATION FOR UV/EUV ASTRONOMY AND SOLAR MISSIONS, 2000, 4139 : 34 - 42
  • [8] IMAGING PROPERTIES OF A DELAY-LINE READOUT USING LARGE MICROCHANNEL PLATES
    SHEPHERD, JA
    SOBOTTKA, SE
    WILLIAMS, MB
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) : 154 - 157
  • [9] PLANAR DOUBLE DELAY-LINE READOUT TECHNIQUE FOR MICROCHANNEL PLATE DETECTORS
    LAMPTON, M
    SIEGMUND, OHW
    RAFFANTI, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (04) : 1548 - 1549
  • [10] EVALUATION OF AN IMAGING PHOTOTUBE USING MICROCHANNEL PLATES WITH DELAY-LINE READOUT
    WILLIAMS, MB
    SOBOTTKA, SE
    SHEPHERD, JA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) : 148 - 153