ONLINE STANDARD ADDITIONS WITH DIRECT INJECTION NEBULIZATION FOR INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY

被引:56
作者
WIEDERIN, DR
SMYCZEK, RE
HOUK, RS
机构
[1] IOWA STATE UNIV SCI & TECHNOL,US DOE,AMES LAB,AMES,IA 50011
[2] IOWA STATE UNIV SCI & TECHNOL,DEPT CHEM,AMES,IA 50011
关键词
D O I
10.1021/ac00015a024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection method for on-line standard additions is described. A 500-mu-L sample solution is injected into a flowing stream via a metal-free flow injection valve. Standard solutions (50-mu-L) are sequentially introduced through a second valve. The two streams mix in a PEEK tee before they are nebulized into the ICP. The advantages of the method of standard additions for matrix correction are retained, but the time-consuming solution preparation steps for conventional standard additions are eliminated by using flow injection techniques and a direct injection nebulizer. Nine toxic elements in undiluted urine were determined in less than 5 min. Possible effects of sample viscosity on accuracy are investigated. Evidence for a change in the background when seawater is nebulized is also presented.
引用
收藏
页码:1626 / 1631
页数:6
相关论文
共 28 条
[1]   DETERMINATION OF ORGANOMERCURY IN BIOLOGICAL REFERENCE MATERIALS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY USING FLOW-INJECTION ANALYSIS [J].
BEAUCHEMIN, D ;
SIU, KWM ;
BERMAN, SS .
ANALYTICAL CHEMISTRY, 1988, 60 (23) :2587-2590
[2]  
BROWNER RF, 1987, INDUCTIVELY COUPLED, P279
[3]   DETERMINATION OF GOLD AT FEMTOMOLAR LEVELS IN NATURAL-WATERS BY FLOW-INJECTION INDUCTIVELY COUPLED PLASMA QUADRUPOLE MASS-SPECTROMETRY [J].
FALKNER, KK ;
EDMOND, JM .
ANALYTICAL CHEMISTRY, 1990, 62 (14) :1477-1481
[4]   STABLE ISOTOPE-DILUTION ANALYSIS OF HYDROLOGIC SAMPLES BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
GARBARINO, JR ;
TAYLOR, HE .
ANALYTICAL CHEMISTRY, 1987, 59 (11) :1568-1575
[5]   INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
HOUK, RS ;
THOMPSON, JJ .
MASS SPECTROMETRY REVIEWS, 1988, 7 (04) :425-461
[6]   ANALYSIS OF SOLUTIONS CONTAINING HIGH-LEVELS OF DISSOLVED SOLIDS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
HUTTON, RC ;
EATON, AN .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (04) :547-550
[7]   FLOW-INJECTION SAMPLE-TO-STANDARD ADDITIONS METHOD - SPECTROPHOTOMETRIC DETERMINATION OF HYDROCHLORIC-ACID AND ORTHO-PHOSPHATE [J].
ISRAEL, Y ;
BARNES, RM .
ANALYST, 1989, 114 (07) :843-848
[8]  
Jarvis K. E., 1991, HDB INDUCTIVELY COUP
[9]   EVALUATION OF INDUCTIVELY COUPLED ARGON PLASMA MASS-SPECTROMETRY (ICP-MS) FOR SIMULTANEOUS MULTI-ELEMENT TRACE ANALYSIS IN CLINICAL-CHEMISTRY [J].
LYON, TDB ;
FELL, GS ;
HUTTON, RC ;
EATON, AN .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (01) :265-271
[10]  
MACHIZUKI T, 1990, ANAL SCI, V6, P191