Truly Distributed Optical Fiber Sensors for Structural Health Monitoring: From the Telecommunication Optical Fiber Drawling Tower to Water Leakage Detection in Dikes and Concrete Structure Strain Monitoring

被引:47
作者
Henault, Jean-Marie [1 ]
Moreau, Gautier [1 ]
Blairon, Sylvain [1 ]
Salin, Jean [1 ]
Courivaud, Jean-Robert [2 ]
Taillade, Frederic [3 ]
Merliot, Erick [3 ]
Dubois, Jean-Philippe [4 ]
Bertrand, Johan [4 ]
Buschaert, Stephane [4 ]
Mayer, Stefan [4 ]
Delepine-Lesoille, Sylvie [3 ,4 ]
机构
[1] EDF R&D, F-78401 Chatou, France
[2] EDF CIH, F-73370 Le Bourget Du Lac, France
[3] LCPC, 58 Bld Lefebvre, F-75015 Paris, France
[4] Andra, F-92298 Chatenay Malabry, France
关键词
D O I
10.1155/2010/930796
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Although optical fiber sensors have been developed for 30 years, there is a gap between lab experiments and field applications. This article focuses on specific methods developed to evaluate the whole sensing chain, with an emphasis on (i) commercially-available optoelectronic instruments and (ii) sensing cable. A number of additional considerations for a successful pairing of these two must be taken into account for successful field applications. These considerations are further developed within this article and illustrated with practical applications of water leakage detection in dikes and concrete structures monitoring, making use of distributed temperature and strain sensing based on Rayleigh, Raman, and Brillouin scattering in optical fibers. They include an adequate choice of working wavelengths, dedicated localization processes, choices of connector type, and further include a useful selection of traditional reference sensors to be installed nearby the optical fiber sensors, as well as temperature compensation in case of strain sensing.
引用
收藏
页数:13
相关论文
共 39 条
[31]  
Lopez-Higuera J. M., 2002, HDB OPTICAL FIBER SE
[32]   Simple distributed fiber sensor based on Brillouin gain spectrum analysis [J].
Nikles, M ;
Thevenaz, L ;
Robert, PA .
OPTICS LETTERS, 1996, 21 (10) :758-760
[33]   Distributed optical-fibre sensing [J].
Rogers, A .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1999, 10 (08) :R75-R99
[34]  
ROGERS AJ, 1981, APPL OPTICS, V20, P1060, DOI 10.1364/AO.20.001060
[35]   Distributed fiber sensing using Brillouin echoes [J].
Thevenaz, Luc ;
Mafang, Stella Foaleng .
19TH INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS, PTS 1 AND 2, 2008, 7004 :N43-N43
[36]   Landau Placzek ratio applied to distributed fibre sensing [J].
Wait, PC ;
Newson, TP .
OPTICS COMMUNICATIONS, 1996, 122 (4-6) :141-146
[37]   Fiber optic sensor for the monitoring of mixed mode cracks in structures [J].
Wan, Kai Tai ;
Leung, Christopher K. Y. .
SENSORS AND ACTUATORS A-PHYSICAL, 2007, 135 (02) :370-380
[38]   Coherent probe-pump-based Brillouin sensor for centimeter-crack detection [J].
Zou, LF ;
Bao, XY ;
Wan, YD ;
Chen, L .
OPTICS LETTERS, 2005, 30 (04) :370-372
[39]   Dependence of the Brillouin frequency shift on strain and temperature in a photonic crystal fiber [J].
Zou, LF ;
Bao, XY ;
Afshar, VS ;
Chen, L .
OPTICS LETTERS, 2004, 29 (13) :1485-1487