PULMONARY-ARTERY AND NONINVASIVE HEMODYNAMICS DURING LUNG LAVAGE IN PRIMARY ALVEOLAR PROTEINOSIS

被引:11
作者
HEMSTAD, JR
SPIESS, BD
MARCHIORO, TL
RAGHU, G
机构
[1] UNIV WASHINGTON,DEPT ANESTHESIOL RN10,DIV CARDIOTHORAC ANESTHESIOL,SEATTLE,WA 98195
[2] UNIV WASHINGTON,DEPT SURG,SEATTLE,WA 98195
[3] UNIV WASHINGTON,DEPT MED,DIV PULM & CRIT CARE MED,CHEST CLIN,SEATTLE,WA
关键词
D O I
10.1378/chest.105.5.1605
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Noninvasive hemodynamic monitoring by bioimpedance has been compared to cardiac output measured by thermodilution. The technology of bioimpedance does allow for monitoring of static thoracic impedance, a measurement thought to be affected by extravascular lung water. No contemporary studies (in the last 20 years) have examined the effectiveness of that parameter in measuring changes in lung water. This case report notes hemodynamics and examines thoracic impedance in a patient undergoing unilateral lung lavage. The hemodynamic data measured by bioimpedance and thermodilution correlated well (r=0.97 for cardiac output). The changes in static impedance were compared to thoracic compliance during infusion of saline solution and evacuation. The changes in both parameters followed each other closely. Further work is required in patients with pulmonary edema or effusions before can be used to monitor such clinical events.
引用
收藏
页码:1605 / 1608
页数:4
相关论文
共 12 条
[1]   CONTINUOUS NONINVASIVE REAL-TIME MONITORING OF STROKE VOLUME AND CARDIAC-OUTPUT BY THORACIC ELECTRICAL BIOIMPEDANCE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :898-901
[2]   PULMONARY LAVAGE IN TREATMENT OF ALVEOLAR PROTEINOSIS [J].
BUSQUE, L .
CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1977, 24 (03) :380-389
[3]  
CLAYPOOL WD, 1988, PULMONARY DISEASES D, V1, P893
[4]  
EISENKRATI J, 1991, THORACIC ANESTHESIA, P419
[5]  
ELLIS JE, 1989, ANESTH ANALG, V68, P777
[6]   CLINICAL EVALUATION OF TRANSTHORACIC ELECTRICAL IMPEDANCE AS A GUIDE TO INTRATHORACIC FLUID VOLUMES [J].
POMERANTZ, M ;
DELGADO, F ;
EISEMAN, B .
ANNALS OF SURGERY, 1970, 171 (05) :686-+
[7]   MULTICOMPONENT NONINVASIVE PHYSIOLOGIC MONITORING OF CIRCULATORY FUNCTION [J].
SHOEMAKER, WC ;
APPEL, PL ;
KRAM, HB ;
NATHAN, RC ;
THOMPSON, JL .
CRITICAL CARE MEDICINE, 1988, 16 (05) :482-490
[8]  
Siegel L C, 1988, J Cardiothorac Anesth, V2, P590, DOI 10.1016/0888-6296(88)90049-X
[9]   INTRATHORACIC PRESSURE, PULMONARY VASCULAR PRESSURES AND GAS EXCHANGE DURING PULMONARY LAVAGE [J].
SMITH, JD ;
MILLEN, JE ;
SAFAR, P ;
ROBIN, ED .
ANESTHESIOLOGY, 1970, 33 (04) :401-&
[10]   BIOIMPEDANCE HEMODYNAMICS COMPARED TO PULMONARY-ARTERY CATHETER MONITORING DURING ORTHOTOPIC LIVER-TRANSPLANTATION [J].
SPIESS, BD ;
MCCARTHY, RJ ;
TUMAN, KJ ;
IVANKOVICH, AD .
JOURNAL OF SURGICAL RESEARCH, 1993, 54 (01) :52-56