IMPEDANCE AND WAVE REFLECTION IN ARTERIAL SYSTEM - SIMULATION WITH GEOMETRICALLY TAPERED T-TUBES

被引:3
作者
CHANG, KC
TSENG, YZ
KUO, TS
CHEN, HI
机构
[1] NATL TAIWAN UNIV, INST ELECT ENGN, BIOMED ENGN SECT, TAIPEI 10764, TAIWAN
[2] TZU CHI MED RES CTR, CARDIOVASC RES LAB, HUALIEN, TAIWAN
关键词
ARTERIAL INPUT IMPEDANCE; ASYMMETRIC T-TUBE MODEL; GEOMETRIC NONUNIFORMITY; TRIANGULARLY TAPERED TRANSMISSION LINE;
D O I
10.1007/BF02510782
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The aortic input impedance is simulated by an asymmetric T-tube model loaded with complex loads. A geometric tapering is incorporated to represent the vasculature, assuming a triangular distribution of the wave transmission paths. Parametric analyses using physiological data demonstrate that the predicted impedance and reflection coefficient spectrum (RCS) closely mimic the experimental data. The simulation also reveals several significant features. As diameter tapering can minimise the presence and influence of wave reflections, the impedance modulus stays relatively constant with two distinct minima. The frequency of first minimum of impedance modulus is evidence of the tube elasticity and load compliance in the lower extremity, and the frequency of second minimum is evidence of those in the upper extremity. The high-frequency portion of the impedance modulus is affected by the tube elasticity, but not by the load compliance. The impedance spectrum at higher frequencies shows no notable fluctuations corresponding to a decrease in blood or wall viscosity. Furthermore, the low-frequency range in RCS is dominated by the longer lower body tube, and the high-frequency range by the shorter upper body tube. This geometrically tapered T-tube is considered a more natural model for the description of the systemic arterial system.
引用
收藏
页码:652 / 660
页数:9
相关论文
共 31 条
[1]   INFLUENCE OF MEAN PRESSURE ON AORTIC IMPEDANCE AND REFLECTIONS IN THE SYSTEMIC ARTERIAL SYSTEM [J].
ALEXANDER, J ;
BURKHOFF, D ;
SCHIPKE, J ;
SAGAWA, K .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (03) :H969-H978
[2]  
Atabek H. B., 1980, BASIC HEMODYNAMICS I, P255
[3]   MULTI-BRANCHED MODEL OF THE HUMAN ARTERIAL SYSTEM [J].
AVOLIO, AP .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1980, 18 (06) :709-718
[4]  
Bergel D. H., 1960, THESIS U LONDON
[5]   DYNAMIC ELASTIC PROPERTIES OF ARTERIAL WALL [J].
BERGEL, DH .
JOURNAL OF PHYSIOLOGY-LONDON, 1961, 156 (03) :458-&
[6]   PULMONARY VASCULAR IMPEDANCE IN DOG [J].
BERGEL, DH ;
MILNOR, WR .
CIRCULATION RESEARCH, 1965, 16 (05) :401-&
[7]   2 ARTERIAL EFFECTIVE REFLECTING SITES MAY APPEAR AS ONE TO THE HEART [J].
BURATTINI, R ;
KNOWLEN, GG ;
CAMPBELL, KB .
CIRCULATION RESEARCH, 1991, 68 (01) :85-99
[8]   MODIFIED ASYMMETRIC T-TUBE MODEL TO INFER ARTERIAL WAVE REFLECTION AT THE AORTIC ROOT [J].
BURATTINI, R ;
CAMPBELL, KB .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (08) :805-814
[9]   ASSESSMENT OF WINDKESSEL AS A MODEL OF AORTIC INPUT IMPEDANCE [J].
BURKHOFF, D ;
ALEXANDER, J ;
SCHIPKE, J .
AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 255 (04) :H742-H753
[10]   TIME-DOMAIN FORMULATION OF ASYMMETRIC T-TUBE MODEL OF ARTERIAL SYSTEM [J].
CAMPBELL, KB ;
BURATTINI, R ;
BELL, DL ;
KIRKPATRICK, RD ;
KNOWLEN, GG .
AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 258 (06) :H1761-H1774