MONITORING OF CENTRAL VENOUS OXYGEN-SATURATION VERSUS MIXED VENOUS OXYGEN-SATURATION IN CRITICALLY ILL PATIENTS

被引:66
作者
MARTIN, C
AUFFRAY, JP
BADETTI, C
PERRIN, G
PAPAZIAN, L
GOUIN, F
机构
[1] Department of Anesthesia and Intensive Care, Hôpital Sainte Marguerite, Marseille Cedex 09, F-13274
关键词
CENTRAL VENOUS CATHETER; CENTRAL VENOUS OXYGEN SATURATION; MIXED VENOUS OXYGEN SATURATION; PULMONARY ARTERY CATHETER;
D O I
10.1007/BF01705041
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Continuous monitoring of mixed venous (SvO2) and central venous (ScO2) oxygen saturation was compared in 7 critically-ill patients (Apache II score: 19 +/- 2. 1 ) to determine whether or not information derived from ScO2 were reliable in clinical practice. Patients were catheterized with both a pulmonary artery (PA) and a central venous (CV) catheter, each of them mounted with fiberoptic sensors (Opticath PA Catheter P7110 and Opticath CV Catheter U440, Abbott). A total of 580 comparative measurements were obtained during periods without and with therapeutic interventions (drug-titration, bronchial suction, use of PEEP, changes in FiO2...). The systematic error between the 2 measurement techniques was 0.6% and 0.3% in periods with and without therapeutic interventions, respectively. The variability between the 2 techniques was 10% for both periods. Differences between the values were greater-than-or-equal-to 5% in 49% of values during periods of stability and in 50% of values during periods with therapeutic interventions. There were poor correlations between the values during periods without (r = 0.48) and with therapeutic interventions (r = 0.62). Better, but still less than ideal, correlations were obtained with changes in SvO2 and ScO2 during periods without (r = 0.70) and with therapeutic interventions (r = 0.77). Although there is a need to develop a simple technique to monitor mixed venous oxygen saturation, the present study indicates that ScO2 monitoring was not reliable in the study patients.
引用
收藏
页码:101 / 104
页数:4
相关论文
共 19 条
[1]  
BAELE PL, 1982, ANESTH ANALG, V61, P513
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   COMPARATIVE-STUDY ON THE CALCULATION OF INTRA-PULMONARY RIGHT-TO-LEFT SHUNT USING CENTRAL VENOUS AND MIXED VENOUS-BLOOD [J].
BRANDL, M ;
PASCH, T ;
KAMP, HD ;
HAERTL, L .
CRITICAL CARE MEDICINE, 1981, 9 (03) :272-272
[4]  
CARGILL WH, 1949, J CLIN INVEST, V28, P226
[5]  
CIVETTA JM, 1980, CRITICAL CARE STATE, V1
[6]   CENTRAL MIXED AND SPLANCHNIC VENOUS OXYGEN-SATURATION MONITORING [J].
DAHN, MS ;
LANGE, MP ;
JACOBS, LA .
INTENSIVE CARE MEDICINE, 1988, 14 (04) :373-378
[7]   CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION [J].
DIVERTIE, MB ;
MCMICHAN, JC .
CHEST, 1984, 85 (03) :423-428
[8]  
KYFF JV, 1989, CHEST, V96, P607
[9]   CARDIAC-OUTPUT AND ITS DISTRIBUTION IN PERITONITIS (SEPTIC) SHOCK IN THE RAT [J].
MARTINELL, S ;
HOGSTROM, H ;
HAGLUND, U .
RESEARCH IN EXPERIMENTAL MEDICINE, 1987, 187 (02) :87-94
[10]   CONTINUOUS VENOUS OXIMETRY IN SURGICAL PATIENTS [J].
NELSON, LD .
ANNALS OF SURGERY, 1986, 203 (03) :329-333