SCLERAL PLUG OF BIODEGRADABLE POLYMERS FOR A CONTROLLED DRUG RELEASE IN THE VITREOUS

被引:0
|
作者
HASHIZOE, M [1 ]
OGURA, Y [1 ]
KIMURA, H [1 ]
HONDA, Y [1 ]
KYO, M [1 ]
HYON, SH [1 ]
IKADA, Y [1 ]
机构
[1] KYOTO UNIV,KYOTO 606,JAPAN
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
引用
收藏
页码:1489 / 1489
页数:1
相关论文
共 50 条
  • [1] SCLERAL PLUG OF BIODEGRADABLE POLYMERS FOR CONTROLLED DRUG-RELEASE IN THE VITREOUS
    HASHIZOE, M
    OGURA, Y
    KIMURA, H
    MORITERA, T
    HONDA, Y
    KYO, M
    HYON, SH
    IKADA, Y
    ARCHIVES OF OPHTHALMOLOGY, 1994, 112 (10) : 1380 - 1384
  • [2] Synthesis of biodegradable polymers for controlled drug release
    Ulbrich, K
    Pechar, M
    Strohalm, J
    Subr, V
    Rihová, B
    BIOARTIFICIAL ORGANS: SCIENCE, MEDICINE, AND TECHNOLOGY, 1997, 831 : 47 - 56
  • [3] Scleral plug of biodegradable polymers containing immunosuppressant for experimental uveitis
    Sakurai, E
    Nozaki, M
    Kunou, N
    Okabe, T
    Kimura, H
    Ogura, Y
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U518 - U518
  • [4] Scleral plug of biodegradable polymers containing ganciclovir for experimental cytomegalovirus retinitis
    Sakurai, E
    Matsuda, Y
    Ozeki, H
    Kunou, N
    Nakajima, K
    Ogura, Y
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (09) : 2043 - 2048
  • [5] Biodegradable scleral implant for intravitreal controlled release of fluconazole
    Miyamoto, H
    Ogura, Y
    Hashizoe, M
    Kunou, N
    Honda, Y
    Ikada, Y
    CURRENT EYE RESEARCH, 1997, 16 (09) : 930 - 935
  • [6] Biodegradable scleral implant for intravitreal controlled release of ganciclovir
    T. Yasukawa
    H. Kimura
    N. Kunou
    H. Miyamoto
    Y. Honda
    Y. Ogura
    Y. Ikada
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2000, 238 : 186 - 190
  • [7] Biodegradable scleral implant for intravitreal controlled release of ganciclovir
    Yasukawa, T
    Kimura, H
    Kunou, N
    Miyamoto, H
    Honda, Y
    Ogura, Y
    Ikada, Y
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (02) : 186 - 190
  • [8] Scleral plug of biodegradable polymers containing ganciclovir for the treatment of cytomegalovirus chorioretinitis.
    Sakurai, E
    Ozeki, H
    Matsuda, Y
    Kunou, N
    Nakajima, K
    Ogura, Y
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S352 - S352
  • [9] Controlled drug release from biodegradable shape-memory polymers
    Wischke, Christian
    Neffe, Axel T.
    Lendlein, Andreas
    Advances in Polymer Science, 2010, 226 (01) : 177 - 205
  • [10] Controlled Drug Release from Biodegradable Shape-Memory Polymers
    Wischke, Christian
    Neffe, Axel T.
    Lendlein, Andreas
    SHAPE-MEMORY POLYMERS, 2010, 226 : 177 - 205