On the Adequacy of API 521 Relief-Valve Sizing Method for Gas-Filled Pressure Vessels Exposed to Fire

被引:6
作者
Andreasen, Anders [1 ]
Borroni, Filippo [2 ]
Nieto, Marcos Zan [2 ]
Stegelmann, Carsten [1 ]
Nielsen, Rudi P. [2 ]
机构
[1] Ramboll Energy, Proc & Tech Safety, Bavnehojvej 5, DK-6700 Esbjerg, Denmark
[2] Aalborg Univ, Dept Chem & Biosci, Niels Bohrs Vej 8A, DK-6700 Esbjerg, Denmark
来源
SAFETY | 2018年 / 4卷 / 01期
关键词
jet fire; pressure relief valve (PRV); vessel rupture; fire heat load; pool fire;
D O I
10.3390/safety4010011
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
In this paper, the adequacy of the legacy API 521 guidance on pressure relief valve (PRV) sizing for gas-filled vessels subjected to external fire is investigated. Multiple studies show that in many cases, the installation of a PRV offers little or no protection-therefore provides an unfounded sense of security. Often the vessel wall will be weakened by high temperatures, before the PRV relieving pressure is reached. In this article, a multiparameter study has been performed taking into consideration various vessel sizes, design pressures (implicitly vessel wall thickness), vessel operating pressure, fire type (pool fire or jet fire) by applying the methodology presented in the Scandpower guideline. A transient thermomechanical response analysis has been carried out to accurately determine vessel rupture times. It is demonstrated that only vessels with relatively thick walls, as a result of high design pressures, benefit from the presence of a PRV, while for most cases no appreciable increase in the vessel survival time beyond the onset of relief is observed. For most of the cases studied, vessel rupture will occur before the relieving pressure of the PRV is reached.
引用
收藏
页数:17
相关论文
共 33 条
[1]  
American Petroleum Institute,, 2014, 521 API, V6th
[2]  
American Petroleum Institute, 2001, REC PRACT AN DES INS
[3]  
American Petroluem Institute, 2008, 520 API
[4]  
Andreasen A, 2015, OIL GAS J, V113, P88
[5]  
[Anonymous], [No title captured]
[6]  
ASME, 2013, ASME INT BOIL PRESS
[7]   On the response of 500 gal propane tanks to a 25% engulfing fire [J].
Birk, A. M. ;
Poirier, D. ;
Davison, C. .
JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2006, 19 (06) :527-541
[8]   Application and validation of the API analytical fire method in pressure-relieving and depressuring systems [J].
Biswas, Souvik ;
Fischer, Benjamin J. .
JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2017, 50 :154-164
[9]   Analysis of Pressure Safety Valves for fire protection on offshore oil and gas installations [J].
Bjerre, Michael ;
Eriksen, Jacob G. I. ;
Andreasen, Anders ;
Stegelmann, Carsten ;
Mando, Matthias .
PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2017, 105 :60-68
[10]   Numerical Simulation of Tanks Containing Pressurized Gas Exposed to Accidental Fires: Evaluation of the Transient Heat Up [J].
D'Aulisa, Arianna ;
Simone, Davide ;
Landucci, Gabriele ;
Tugnoli, Alessandro ;
Cozzani, Valerio ;
Birk, Michael .