STEREOTAXIC RADIOTHERAPY OF MALIGNANCIES IN THE ABDOMEN - METHODOLOGICAL ASPECTS

被引:396
作者
LAX, I
BLOMGREN, H
NASLUND, I
SVANSTROM, R
机构
[1] KAROLINSKA HOSP,DEPT ONCOL,S-10401 STOCKHOLM,SWEDEN
[2] KAROLINSKA HOSP,DEPT DIAGNOST RADIOL,S-10401 STOCKHOLM,SWEDEN
关键词
D O I
10.3109/02841869409121782
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A method for sterotactic high-dose radiotherapy of malignancies in the abdomen has been developed. A stereotactic frame for the body has been developed and a method for fixation of the patient in the frame is described. The reproducibility in the stereotactic system of tumours in the liver and the lung was found to be within 5-8 mm for 90% of the patient set-ups. The diaphragmatic movements were reduced to 5-10 mm, by applying a pressure on the abdomen. An analytical method is used to calculate dose distributions for a continuum of beams in an isocentric treatment technique. The advantage of a heterogeneous target dose is demonstrated and proposed for the present application. A non-coplanar treatment technique, using eight individually shaped beams is proposed and has been used for patient treatments. The dose distribution for a patient with a metastasis in the liver is shown as well as dose volume histograms for the target and the liver.
引用
收藏
页码:677 / 683
页数:7
相关论文
共 11 条
  • [1] TISSUE TOLERANCE OF NORMAL AND SURGICALLY MANIPULATED CANINE LIVER TO INTRAOPERATIVE RADIATION-THERAPY (IORT)
    CROMHEECKE, M
    VERMEIJ, J
    GROND, AJK
    KONINGS, AWT
    OLDHOFF, J
    HOEKSTRA, HJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (05): : 1141 - 1146
  • [2] TOLERANCE OF NORMAL TISSUE TO THERAPEUTIC IRRADIATION
    EMAMI, B
    LYMAN, J
    BROWN, A
    COIA, L
    GOITEIN, M
    MUNZENRIDER, JE
    SHANK, B
    SOLIN, LJ
    WESSON, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01): : 109 - 122
  • [3] Fowler JF., 1992, SEMIN RADIAT ONCOL, V2, P16, DOI 10.1016/S1053-4296(05)80045-1
  • [4] A COMPARISON OF TECHNIQUES FOR STEREOTAXIC RADIOTHERAPY BY LINEAR-ACCELERATOR BASED ON 3-DIMENSIONAL DOSE DISTRIBUTIONS
    GRAHAM, JD
    NAHUM, AE
    BRADA, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 1991, 22 (01) : 29 - 35
  • [5] CONCOMITANT BOOST RADIOTHERAPY FOR ADVANCED SQUAMOUS-CELL CARCINOMA OF THE HEAD AND NECK
    KNEE, R
    FIELDS, RS
    PETERS, LJ
    [J]. RADIOTHERAPY AND ONCOLOGY, 1985, 4 (01) : 1 - 7
  • [6] STEREOTAXIC RADIOTHERAPY OF IRREGULAR TARGETS - A COMPARISON BETWEEN STATIC CONFORMAL BEAMS AND NONCOPLANAR ARCS
    LAING, RW
    BENTLEY, RE
    NAHUM, AE
    WARRINGTON, AP
    BRADA, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 1993, 28 (03) : 241 - 246
  • [7] THE RADIOBIOLOGY OF RADIOSURGERY
    LARSON, DA
    FLICKINGER, JC
    LOEFFLER, JS
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (03): : 557 - 561
  • [8] THE USE OF 3-D-DOSE VOLUME ANALYSIS TO PREDICT RADIATION HEPATITIS
    LAWRENCE, TS
    TENHAKEN, RK
    KESSLER, ML
    ROBERTSON, JM
    LYMAN, JT
    LAVIGNE, ML
    BROWN, MB
    DUROSS, DJ
    ANDREWS, JC
    ENSMINGER, WD
    LICHTER, AS
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 23 (04): : 781 - 788
  • [9] TARGET DOSE VERSUS EXTRATARGET DOSE IN STEREOTAXIC RADIOSURGERY
    LAX, I
    [J]. ACTA ONCOLOGICA, 1993, 32 (04) : 453 - 457
  • [10] THE SIMULTANEOUS BOOST TECHNIQUE - THE CONCEPT OF RELATIVE NORMALIZED TOTAL DOSE
    LEBESQUE, JV
    KEUS, RB
    [J]. RADIOTHERAPY AND ONCOLOGY, 1991, 22 (01) : 45 - 55