ECHOCARDIOGRAPHIC DEMONSTRATION OF MITRAL PARAVALVULAR REGURGITATION WITH A ST-JUDE-MEDICAL HEART-VALVE PROTHESIS

被引:0
|
作者
JANSEN, W
BRECHT, R
HOMBACH, V
TAUCHERT, M
ARNOLD, G
KAISER, C
LUBBING, H
机构
[1] UNIV COLOGNE,LEHRSTUHL INNERE MED 3,MED KLIN & POLIKLIN,D-5000 COLOGNE 41,FED REP GER
[2] UNIV COLOGNE,KARDIOL ABT,D-5000 COLOGNE 41,FED REP GER
[3] UNIV COLOGNE,INST PATHOL,D-5000 COLOGNE 41,FED REP GER
[4] UNIV KOLN KLIN,KARDIOCHIRURG ABT,KOLN,FED REP GER
来源
HERZ KREISLAUF | 1982年 / 14卷 / 08期
关键词
D O I
暂无
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
引用
收藏
页码:451 / 458
页数:8
相关论文
共 50 条
  • [1] MALFUNCTION OF A ST JUDE MEDICAL HEART-VALVE IN MITRAL POSITION
    ZIEMER, G
    LUHMER, I
    OELERT, H
    BORST, HG
    ANNALS OF THORACIC SURGERY, 1982, 33 (04) : 391 - 395
  • [2] TRANSESOPHAGEAL ECHOCARDIOGRAPHIC EVALUATION OF ST-JUDE-MEDICAL AND BIOPROSTHETIC VALVE ENDOCARDITIS
    ALAM, M
    ROSMAN, HS
    SUN, I
    AMERICAN HEART JOURNAL, 1992, 123 (01) : 236 - 239
  • [3] ECHOCARDIOGRAPHIC IDENTIFICATION AND ANALYSIS OF FUNCTION OF THE ST-JUDE MEDICAL HEART-VALVE PROSTHESIS
    HIDAJAT, HC
    GOTTWIK, MG
    THORMANN, J
    SCHLEPPER, M
    EUROPEAN JOURNAL OF CARDIOLOGY, 1980, 12 (3-4): : 167 - 176
  • [4] CLINICAL HEMOLYSIS WITH THE ST-JUDE HEART-VALVE WITHOUT PARAVALVULAR LEAK
    BARMADA, H
    STARR, A
    MEDICAL PROGRESS THROUGH TECHNOLOGY, 1994, 20 (3-4) : 191 - 194
  • [5] AUSCULTATION OF THE ST JUDE MITRAL-VALVE PROSTHESIS WITH EMPHASIS ON FINDINGS OF PARAVALVULAR REGURGITATION
    ROSMAN, HS
    ALAM, M
    SHETH, M
    GOLDSTEIN, S
    AMERICAN JOURNAL OF NONINVASIVE CARDIOLOGY, 1991, 5 (06): : 353 - 357
  • [6] EXPERIENCE WITH THE ST-JUDE MEDICAL PROSTHETIC HEART-VALVE
    BRAUN, V
    NIEHUES, B
    LUBBING, H
    BEHRENBECK, DW
    DALICHAU, H
    MEDIZINISCHE WELT, 1980, 31 (31-3): : 1120 - 1123
  • [7] TRANSESOPHAGEAL COLOR FLOW DOPPLER AND ECHOCARDIOGRAPHIC FEATURES OF NORMAL AND REGURGITANT ST-JUDE-MEDICAL PROSTHESES IN THE MITRAL-VALVE POSITION
    ALAM, M
    SERWIN, JB
    ROSMAN, HS
    SHETH, M
    SUN, I
    SILVERMAN, NA
    GOLDSTEIN, S
    AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (10) : 871 - 873
  • [8] PRESSURE LOSS AND VALVE APERTURE DIAMETER IN THE BJORK-SHILEY-CC, OMNISCIENCE, ST-JUDE-MEDICAL AND HALL-KASTER HEART-VALVE PROSTHESES
    KOHLER, J
    EHRENTRAUT, G
    ZEITSCHRIFT FUR KARDIOLOGIE, 1981, 70 (04): : 305 - 305
  • [9] CLINICAL-EVALUATION OF THE ST-JUDE-MEDICAL HEART-VALVE PROSTHESIS - A 2-YEAR FOLLOW-UP OF 150 PATIENTS
    BURCKHARDT, D
    HOFFMANN, A
    VOGT, S
    PFISTERER, M
    HASSE, J
    GRADEL, E
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1984, 88 (03) : 432 - 438
  • [10] NOISE PERCEPTION AND SOUND PRESSURE LEVELS AFTER VALVE-REPLACEMENT WITH ST-JUDE-MEDICAL AND DUROMEDICS-EDWARDS BILEAFLET HEART-VALVE PROSTHESES
    MORITZ, A
    KOBINIA, G
    STEINSEIFER, U
    WOLTERS, H
    REUL, H
    NEUWIRTHRIEDL, K
    MESSMER, B
    RAU, G
    ZEITSCHRIFT FUR KARDIOLOGIE, 1989, 78 (12): : 784 - 789