SOLVENT EFFECTS ON THE REACTIVITIES OF AN AMPEROMETRIC GLUCOSE SENSOR

被引:31
|
作者
IWUOHA, EI [1 ]
SMYTH, MR [1 ]
LYONS, MEG [1 ]
机构
[1] UNIV DUBLIN TRINITY COLL,PHYS CHEM LAB,DUBLIN 2,IRELAND
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 1995年 / 390卷 / 1-2期
关键词
AMPEROMETRY; REACTIVITY; ORGANIC PHASE BIOSENSORS; SOLVENT EFFECTS; GLUCOSE SENSOR;
D O I
10.1016/0022-0728(95)03906-W
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Reactivities of organic phase biosensors containing 5.1 pmol cm(-2) glucose oxidase (GOx) on glassy carbon (GC) or Pt electrode surfaces (0.071 cm(2) in area) were evaluated in acetonitrile, acetone, butan-2-ol, tetrahydrofuran and 0.1 M phosphate buffer (pa 7.0). Each of the organic media contained 10% v/v of water. Ferrocenemonocarboxylic acid was used as a soluble electron transfer mediator for the detection of glucose in these solvents. Tafel analyses of the cyclic voltammograms (CVs) of the electrocatalytic reaction gave Tafel slopes of between 103 and 129 mV decade(-1), which are in good agreement with the theoretical value of 118 mV decade(-1). Constant-potential amperometric studies an GOx-modified rotating Pt disc electrodes (RDEs) were carried out at 0.45 V, a potential dictated by the limiting catalytic currents I-K Of the CV experiments. The apparent turnover rate constant K-cat' of GOx in the biosensor and its catalytic efficiency k(cat)'/K-m' were estimated from the results of the RDE experiments. Changing from the aqueous buffer to organic media produced a drastic decrease in k(cat)', which is more than two orders of magnitude lower in butan-2-ol. This sensor characteristic is related to the lower solvent-dependent diffusibility of glucose in the sensor for the organic systems vis-g-vis phosphate buffer. The normalized catalytic efficiencies, (k(cat)'/K-m')(org) (solv)/(K-cat'/K-m')(buffer) show an enhancement of biosensor efficiency on changing from phosphate buffer to polar organic solvents. The K-cat'/K-m' values are indicators of the degree of activation of the biosensor's electrocatalytic reaction. Greater stabilization of the transition state of the electroenzymatic process by organic phases relative to phosphate buffer was ascertained from the normalized catalytic efficiency. The enhanced catalytic efficiency of the organic phase sensors is attributed solely to the activation of the catalytic reaction of GOx and beta-D-glucose.
引用
收藏
页码:35 / 45
页数:11
相关论文
共 50 条
  • [21] Amperometric glucose sensor for real time extracellular glucose monitoring in microfluidic device
    Ges, Igor A.
    Baudenbacher, Franz J.
    NSTI NANOTECH 2008, VOL 3, TECHNICAL PROCEEDINGS: MICROSYSTEMS, PHOTONICS, SENSORS, FLUIDICS, MODELING, AND SIMULATION, 2008, : 253 - +
  • [22] Escherichia coli and its application in a mediated amperometric glucose sensor
    Ito, Y
    Yamazaki, S
    Kano, K
    Ikeda, T
    BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12): : 993 - 998
  • [23] Amperometric glucose sensor based on platinum-iridium nanomaterials
    Holt-Hindle, Peter
    Nigro, Samantha
    Asmussen, Matt
    Chen, Aicheng
    ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (10) : 1438 - 1441
  • [24] An Interference Study with Different Working Potentials for an Amperometric Glucose Sensor
    Lin, Kuo-Chiang
    Yang, Cheng-Yu
    Chen, Shen-Ming
    Zhao, Dou-Han
    Hou, Yu-Shen
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (03): : 2755 - 2763
  • [25] AMPEROMETRIC GLUCOSE SENSOR WITH TETRATHIAFULVALENE AS AN ELECTRON-TRANSFER MEDIATOR
    SUN, CQ
    YANG, X
    LUAN, CX
    GAO, Q
    XU, HD
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 1995, 11 (03): : 189 - 194
  • [26] AMPEROMETRIC GLUCOSE SENSOR WITH FERROCENE AS AN ELECTRON-TRANSFER MEDIATOR
    DONG, SJ
    WANG, BX
    LIU, BF
    BIOSENSORS & BIOELECTRONICS, 1992, 7 (03): : 215 - 222
  • [27] AMPEROMETRIC GLUCOSE SENSOR - SHORT-TERM, INVIVO TEST
    LEWANDOWSKI, JJ
    SZCZEPANSKASADOWSKA, E
    KRZYMIEN, J
    NALECZ, M
    DIABETES CARE, 1982, 5 (03) : 238 - 244
  • [28] An amperometric glucose sensor with modified Langmuir-Blodgett films
    Tsuji, H
    Mitsubayashi, K
    ELECTROANALYSIS, 1997, 9 (02) : 161 - 164
  • [29] Fabrication of a Flexible Amperometric Glucose Sensor Using Additive Processes
    Du, Xiaosong
    Durgan, Christopher J.
    Matthews, David J.
    Motley, Joshua R.
    Tan, Xuebin
    Pholsena, Kovit
    Arnadottir, Liney
    Castle, Jessica R.
    Jacobs, Peter G.
    Cargill, Robert S.
    Ward, W. Kenneth
    Conley, John F., Jr.
    Hermana, Gregory S.
    ECS JOURNAL OF SOLID STATE SCIENCE AND TECHNOLOGY, 2015, 4 (04) : P3069 - P3074
  • [30] AN AMPEROMETRIC GLUCOSE SENSOR BASED ON GLUCOSE-OXIDASE ADSORBED ON A NONPOROUS CARBON ELECTRODE
    GORTON, L
    SCHELLER, F
    JOHANSSON, G