PACEMAKER MEDIATED TACHYCARDIAS IN SINGLE CHAMBER RATE RESPONSIVE PACING

被引:9
作者
LAU, CP
TAI, YT
FONG, PC
CHENG, CH
CHUNG, FLW
机构
[1] Division of Cardiology, Department of Medicine, University of Hong Kong
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1990年 / 13卷 / 12期
关键词
PACEMAKER MEDIATED TACHYCARDIA; TWIDDLERS SYNDROME; RATE RESPONSIVE PACING;
D O I
10.1111/j.1540-8159.1990.tb06856.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although pacemaker mediated tachycardias are classically associated with dual chamber pacemakers, single chamber rate responsive pacemakers are also susceptible to such tachycardias under special circumstances. A unipolar activity sensing rate responsive pacemaker (Activitrax 8403) was implanted in an 83-year-old man with complete atrioventricular block. The pacemaker was programmed at an output of 5 V, activity threshold medium, rate response 5, and lower and upper rates of 70 and 125 beats/min, respectively. He presented with palpitations at rest and muscle twitching of the pacemaker pocket 4 months after implantation. Examination confirmed that the pacemaker had flipped over, resulting in pocket pacing which in turn activated the activity sensor, resulting in a rate response. The increase in pacing rate lead to a higher frequency of pocket pacing, thus leading to positive feedback increase in rate. With the patient at rest, pacemaker mediated rates were 106, 91, and 74 beats/min at low, medium and high thresholds, respectively. Decreasing the output to 2.5 V eliminated pocket pacing and the tachycardia. As a result of the reversal of the pacemaker, a similar rate response during exercise could only be achieved at a more sensitive rate responsive setting. Thus, pacemaker mediated tachycardia can complicate pacemaker "flipping" in single chamber activity sensing rate responsive pacemakers. Methods for the avoidance and treatment of pacemaker flipping are discussed. A review of other sensor mediated tachycardias is also presented.
引用
收藏
页码:1575 / 1579
页数:5
相关论文
共 15 条
  • [1] ALT E, 1987, PACE, V10, P1206
  • [2] IMPROVED PATTERN OF RATE RESPONSIVENESS WITH DYNAMIC SLOPE SETTING FOR THE QT SENSING PACEMAKER
    BAIG, MW
    WILSON, J
    BOUTE, W
    BEGEMANN, MJS
    COBBOLD, JP
    PERRINS, EJ
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (02): : 311 - 320
  • [3] BAYLISS CE, 1968, CAN MED ASSOC J, V99, P371
  • [4] ENDLESS LOOP TACHYCARDIA IN AN AV UNIVERSAL (DDD) PACEMAKER
    FURMAN, S
    FISHER, JD
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1982, 5 (04): : 486 - 489
  • [5] FURMAN SC, COMMUNICATION
  • [6] SINGLE-CHAMBER CARDIAC PACING WITH 2 FORMS OF RESPIRATION-CONTROLLED RATE-RESPONSIVE PACEMAKER
    LAU, CP
    WARD, DE
    CAMM, AJ
    [J]. CHEST, 1989, 95 (02) : 352 - 358
  • [7] RATE MODULATION BY ARM MOVEMENTS OF THE RESPIRATORY DEPENDENT RATE RESPONSIVE PACEMAKER
    LAU, CP
    RITCHE, D
    BUTROUS, GS
    WARD, DE
    CAMM, AJ
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (06): : 744 - 752
  • [8] CLINICAL-EXPERIENCE WITH SENSOLOG-703 - A NEW ACTIVITY SENSING RATE RESPONSIVE PACEMAKER
    LAU, CP
    TSE, WS
    CAMM, AJ
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (10): : 1444 - 1455
  • [9] RELIABILITY OF MINUTE VENTILATION AS A PARAMETER FOR RATE RESPONSIVE PACING
    LAU, CP
    ANTONIOU, A
    WARD, DE
    CAMM, AJ
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1989, 12 (02): : 321 - 330
  • [10] PARSONNET V, 1972, ARCH SURG-CHICAGO, V105, P654