摘要
Two methods for the determination of cadmium and lead based on graphite furnace atomic absorption spectrometry (GFAAS) with Zeeman background correction are described. The main difference between the methods is the method of sample destruction, bomb digestion versus dry ashing. The precision and accuracy of the methods has been tested by analyzing 16 different reference materials, with cadmium concentrations varying from 2.9 μg/kg to 2.7 mg/kg and lead concentrations from 44 μg/kg to 13.5 mg/kg. The methods produced results which differ, with a few exceptions, less than 10% from the certified contents, with relative standard deviations of around 5%. The methods are not difficult to carry out, are not very laborious and without modifications are applicable to a large variety of products. The sample solutions obtained can also be used for the determination of other elements, e.g. Al, Cr, Cu, Hg, Mn, Ni and Zn. The detection limits, for test portions of 1 and 5 g (wet products) are 0.5-1 μg/kg for cadmium and 5-20 μg/kg for lead. © 1990 Taylor & Francis Ltd.
引用
收藏
页码:265 / 273
页数:9
相关论文
共 50 条
  • [31] Determination of cadmium, chromium and lead in Lycoris radiata with microwave digestion technique by graphite furnace atomic absorption spectrometry
    Fan, HJ
    Li, GK
    Luan, W
    Cai, PX
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25 (09) : 1503 - 1506
  • [32] METHODS VALIDATION FOR DETERMINATION OF LEAD, CADMIUM AND TIN IN FRUIT JUICES BY MEANS OF GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY
    Nour, V.
    Trandafir, I.
    Ionica, M. E.
    JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2011, 12 (4A): : 2046 - 2055
  • [33] Determination of cadmium and lead in reference materials by volatile species generation with in situ trapping flame atomic absorption spectrometry
    Matusiewicz, Henryk
    Krawczyk, Magdalena
    MICROCHEMICAL JOURNAL, 2006, 83 (01) : 17 - 23
  • [34] Effectiveness of Palladium–Sodium Azide Modifier for the Direct Determination of Urinary Cadmium by Graphite-Furnace Atomic Absorption Spectrometry
    Sibel Saraçoğlu
    Latif Elçi
    Analytical Sciences, 1999, 15 : 569 - 573
  • [35] Determination of lead and cadmium in food and blood by inductively coupled plasma mass spectrometry: a comparison with graphite furnace atomic absorption spectrometry
    Zhang, ZW
    Shimbo, S
    Ochi, N
    Eguchi, M
    Watanabe, T
    Moon, CS
    Ikeda, M
    SCIENCE OF THE TOTAL ENVIRONMENT, 1997, 205 (2-3) : 179 - 187
  • [36] Determination of cadmium and lead in tap water by graphite-furnace atomic absorption spectrometry after preconcentration on a finely divided ion-exchange resin as the pyrrolidinedithiocarbamate complexes
    Anezaki, K
    Chen, XZ
    Ogasawara, T
    Nukatsuka, I
    Ohzeki, K
    ANALYTICAL SCIENCES, 1998, 14 (03) : 523 - 527
  • [37] Determination of Cadmium and Lead in Tap Water by Graphite-Furnace Atomic Absorption Spectrometry after Preconcentration on a Finely Divided Ion-Exchange Resin as the Pyrrolidinedithiocarbamate Complexes
    Katsunori Anezaki
    Xueze Chen
    Tamotsu Ogasawara
    Isoshi Nukatsuka
    Kunio Ohzeki
    Analytical Sciences, 1998, 14 : 523 - 527
  • [38] Validation of Cadmium Determination in Polyethylene Reference Materials by Means of Solid Sampling Zeeman Atomic Absorption Spectrometry
    Detcheva, Albena K.
    Grobecker, Karl H.
    EURASIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 3 (01): : 70 - 78
  • [39] DETERMINATION OF LEAD IN CROATIAN WINES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY
    Tariba, Blanka
    Pizent, Alica
    Kljakovia-Gaspic, Zorana
    ARHIV ZA HIGIJENU RADA I TOKSIKOLOGIJU-ARCHIVES OF INDUSTRIAL HYGIENE AND TOXICOLOGY, 2011, 62 (01): : 25 - 31
  • [40] Determination of cadmium and lead in beverages after leaching from pewter cups using graphite furnace atomic absorption spectrometry
    Dessuy, Morgana B.
    Vale, Maria Goreti R.
    Welz, Bernhard
    Borges, Aline R.
    Silva, Marcia M.
    Martelli, Patricia B.
    TALANTA, 2011, 85 (01) : 681 - 686