Clinical Features of Cataract Extraction with Negative-Power Intraocular Lens Implantation in High Myopia

被引:0
|
作者
Kim, Min Kyo [1 ,2 ]
Shin, Woo Beom [1 ,2 ]
Jeong, Hyun Kyo [1 ,2 ]
Choi, Jung Bum [1 ]
机构
[1] Siloam Eye Hosp, 181 Deungchon Ro, Seoul 07668, South Korea
[2] Yonsei Univ, Inst Vis Res, Dept Ophthalmol, Coll Med, Seoul, South Korea
来源
JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY | 2016年 / 57卷 / 06期
关键词
Cataract; High myopia; Negative power intraocular lens;
D O I
10.3341/jkos.2016.57.6.898
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the clinical features of high myopic eyes with cataracts implanted with negative power intraocular lenses (IOLs) at the time of cataract surgery. Methods: A retrospective chart review was conducted of 18 eyes of 14 patients who underwent cataract surgery with negative power IOLs and 10 eyes in 9 patients with low power IOLs. We investigated axial length, IOL power, preoperative and postoperative best-corrected visual acuity (BCVA) and preoperative and postoperative spherical equivalent (SE) refractive errors. Results: Mean BCVA showed significant improvement in both groups. We measured postoperative SE refraction and the difference between the mean intended and the mean achieved SE refractive errors in the negative power group (17 eyes) was +1.59 +/- 1.34 D and +0.31 +/- 0.50 D in the low power group. Conclusions: BCVA was significantly improved in the majority of eyes, although they had myopic macular degeneration or posterior staphyloma. However, the mean achieved postoperative SE refraction was more hyperopic than the predicted postoperative SE error. Additionally, hyperopic refractive error was greater in the negative power group than the low power group. Therefore, we recommend that postoperative hyperopic refractive error should be considered when performing cataract surgery in high myopic patients.
引用
收藏
页码:898 / 904
页数:7
相关论文
共 50 条
  • [41] Changes in anterior chamber volume after implantation of posterior chamber phakic intraocular lens in high myopia
    Zhu, Yi
    Zhu, Haobin
    Jia, Yan
    Zhou, Jibo
    BMC OPHTHALMOLOGY, 2018, 18
  • [42] Long-term vision-threatening complications of phakic intraocular lens implantation for high myopia
    Isil Bahar Sayman Muslubas
    Baran Kandemir
    Ayse Yesim Aydin Oral
    Suleyman Kugu
    Metin Dastan
    International Journal of Ophthalmology, 2014, (02) : 376 - 380
  • [43] Changes in anterior chamber volume after implantation of posterior chamber phakic intraocular lens in high myopia
    Yi Zhu
    Haobin Zhu
    Yan Jia
    Jibo Zhou
    BMC Ophthalmology, 18
  • [44] Effectivity and safety of trifocal intraocular lenses and capsular tension rings implantation for cataract patients with axial high myopia
    Hua, Shan
    Xie, Qiu-Xia
    Wang, Hu
    Zhong, Jing-Xiang
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2024, 17 (03) : 499 - 508
  • [45] Accuracy of intraocular lens power calculation using partial coherence interferometry in patients with high myopia
    Roessler, Gernot F.
    Dietlein, Thomas S.
    Plange, Niklas
    Roepke, Anna-Katharina
    Dinslage, Sven
    Walter, Peter
    Mazinani, Babac A.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2012, 32 (03) : 228 - 233
  • [46] COMBINED TRABECULECTOMY, CATARACT-EXTRACTION, AND FOLDABLE LENS IMPLANTATION
    PARKER, JS
    GOLLAMUDI, S
    JOHN, G
    STARK, WJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (06) : 582 - 585
  • [47] Comparison of trifocal toric and bifocal toric intraocular lens implantation in patients with cataract and high corneal astigmatism
    Gencer, Merve Bozkurt
    Basmak, Hikmet
    Yasar, Erdogan
    Onal, Ozkan
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2021, 14 (12) : 1876 - 1881
  • [48] Biometry and intraocular lens power calculation for cataract surgery: an update
    Findl, O.
    SPEKTRUM DER AUGENHEILKUNDE, 2007, 21 (02) : 90 - 93
  • [49] Short-time evaluation on intraocular scattering after implantable collamer lens implantation for correcting high myopia
    Yu, Zhe
    Li, Jun
    Song, Hui
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [50] Short-time evaluation on intraocular scattering after implantable collamer lens implantation for correcting high myopia
    Zhe Yu
    Jun Li
    Hui Song
    BMC Ophthalmology, 20