KINETIC SPECTROFLUOROMETRIC DETERMINATION OF NITRITE AND NITRATE AT THE NANOGRAMS PER MILLILITER LEVEL BY MANUAL AND FLOW-INJECTION METHODS

被引:26
|
作者
PEREZRUIZ, T
MARTINEZLOZANO, C
TOMAS, V
机构
[1] Department of Analytical Chemistry, Faculty of Sciences, University of Murcia
关键词
CATALYTIC METHODS; FLOW INJECTION; FLUOROMETRY; KINETIC METHODS; FOODS; MEAT; NITRATE; NITRITE; WATERS;
D O I
10.1016/0003-2670(92)85160-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The catalytic effect of nitrite on the oxidation of phenosafranine by bromate in acidic medium was studied by using the decrease in fluorescence intensity of phenosafranine. This kinetic-spectrofluorimetric method for nitrite is linear over the range 0.9-13.8 ng ml-1 with a relative standard deviation of about 1.5%. The method can be successfully adapted to flow-injection analysis in the stopped-flow mode. Manual and flow-injection methods were satisfactorily applied to the determination of nitrite in waters and meat products. The inclusion of a copperized cadmium column in the flow system allowed the determination of nitrate and the sequential determination of nitrate and nitrite in mixtures.
引用
收藏
页码:103 / 110
页数:8
相关论文
共 50 条
  • [1] CATALYTIC FLUORIMETRIC DETERMINATION OF COPPER AT THE NANOGRAMS PER MILLILITER LEVEL BY FLOW-INJECTION ANALYSIS
    BOZA, FL
    DECASTRO, MDL
    CASES, MV
    ANALYST, 1984, 109 : 333 - 337
  • [2] Spectrofluorometric determination of hesperidin by manual and flow-injection methods
    T. Pérez-Ruíz
    C. Martínez-Lozano
    V. Tomás
    J. Fenoll
    Fresenius' Journal of Analytical Chemistry, 1999, 364 : 279 - 283
  • [3] Spectrofluorometric determination of hesperidin by manual and flow-injection methods
    Pérez-Ruíz, T
    Martínez-Lozano, C
    Tomás, V
    Fenoll, J
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (03): : 279 - 283
  • [4] Selective kinetic spectrophotometric determination of copper at nanograms per milliliter level
    Safavi, A
    Maleki, N
    Farjami, F
    TALANTA, 2001, 54 (02) : 397 - 402
  • [5] FLUOROMETRIC SENSOR FOR THE DETERMINATION OF FLUORIDE AT THE NANOGRAMS PER MILLILITER LEVEL
    CHEN, D
    DECASTRO, MDL
    VALCARCEL, M
    ANALYTICA CHIMICA ACTA, 1990, 234 (02) : 345 - 352
  • [6] KINETIC PHOTOMETRIC-DETERMINATION OF COPPER AT THE NANOGRAMS PER MILLILITER LEVEL IN REAL SAMPLES
    VELASCO, A
    SILVA, M
    VALCARCEL, M
    ANALYTICA CHIMICA ACTA, 1990, 229 (01) : 107 - 114
  • [7] KINETIC FLOW-INJECTION SPECTROFLUOROMETRIC METHOD FOR THE DETERMINATION OF FLUORIDE
    MARCO, V
    CARRILLO, F
    PEREZCONDE, C
    CAMARA, C
    ANALYTICA CHIMICA ACTA, 1993, 283 (01) : 489 - 493
  • [8] FLUORIMETRIC DETERMINATION OF TIN AT THE NANOGRAMS PER MILLILITER LEVEL IN CANNED BEVERAGES
    RUBIO, S
    GOMEZHENS, A
    VALCARCEL, M
    ANALYST, 1985, 110 (01) : 43 - 45
  • [9] DETERMINATION OF NITRATE AND NITRITE IN SEAWATER BY FLOW-INJECTION ANALYSIS
    JOHNSON, KS
    PETTY, RL
    LIMNOLOGY AND OCEANOGRAPHY, 1983, 28 (06) : 1260 - 1266
  • [10] SIMULTANEOUS DETERMINATION OF NITRATE AND NITRITE BY FLOW-INJECTION ANALYSIS
    GINE, MF
    BERGAMIN, H
    ZAGATTO, EAG
    REIS, BF
    ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) : 191 - 197