A COAXIAL JET MIXER FOR RAPID KINETIC-ANALYSIS IN FLOW-INJECTION AND FLOW INJECT ION CYTOMETRY

被引:42
作者
SCAMPAVIA, LD
BLANKENSTEIN, G
RUZICKA, J
CHRISTIAN, GD
机构
[1] Department of Chemistry BG-10, University of Washington, Seattle
关键词
D O I
10.1021/ac00113a004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple coaxial jet mixer for rapid and efficient confluent mixing under laminar now conditions (Re <5) is described. This device demonstrates exceptional control of mixing between two laminar streams by creating shear forces due to variable now velocities at the point of confluence. It is suitable for flow injection and cytometric analyses of rapid kinetic events which require contact mixing of two solutions and subsecond measurements of the evolving reaction. This apparatus was devised for now injection cytometry as performed on a Becton Dickinson FAGS Analyzer. Under normal cytometric conditions and at a sample introduction rate of 60 mu uL/min, the laminar jet mixer is capable of complete mixing of two solutions within 55 ms. Kinetic measurements can be performed on the FAGS Analyzer in a variable time range of 100 ms to 3 min with 14-30 ms temporal resolution of the studied event. Since no boost in core flow is required, potential spectral distortions due to core now variations are eliminated. This coaxial jet mixer can be easily constructed and employed on a variety of cytometers as well as conventional now injection analysis systems, since it is an effective mixer under most flow conditions.
引用
收藏
页码:2743 / 2749
页数:7
相关论文
共 24 条
  • [1] Bird R.B., 1980, TRANSPORT PHENOMENA
  • [2] BUSLIK DH, 1975, AUG CL 4 CHISA 75
  • [3] Cantor CR, 1980, BIOPHYS CHEM
  • [4] OPTIMIZATION OF CONFLUENT MIXING IN FLOW-INJECTION ANALYSIS
    CLARK, GD
    HUNGERFORD, JM
    CHRISTIAN, GD
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (09) : 973 - 979
  • [5] TIME WINDOW ANALYSIS AND SORTING
    DUNNE, JF
    [J]. CYTOMETRY, 1991, 12 (07): : 597 - 601
  • [6] ELSNER J, 1992, J LEUKOCYTE BIOL, V51, P77
  • [7] Harnby N., 1985, MIXING PROCESS IND
  • [8] VERY EARLY DETECTION OF CHANGES ASSOCIATED WITH CELLULAR ACTIVATION USING A MODIFIED FLOW CYTOMETER
    KELLEY, KA
    [J]. CYTOMETRY, 1991, 12 (05): : 464 - 468
  • [9] ADHERENCE OF HUMAN NEUTROPHILS CHANGES CA-2+ SIGNALING DURING ACTIVATION WITH OPSONIZED PARTICLES
    KOENDERMAN, L
    TOOL, ATJ
    HOOYBRINK, B
    ROOS, D
    HANSEN, CA
    WILLIAMSON, JR
    VERHOEVEN, AJ
    [J]. FEBS LETTERS, 1990, 270 (1-2) : 49 - 52
  • [10] LANGHAAR HL, 1942, J APPL MECH, V9, pA55