AN INVESTIGATION OF EARTHQUAKE INDUCED POUNDING BETWEEN ADJACENT BUILDINGS

被引:231
|
作者
ANAGNOSTOPOULOS, SA [1 ]
SPILIOPOULOS, KV [1 ]
机构
[1] NATL TECH UNIV ATHENS,GR-147 ATHENS,GREECE
关键词
D O I
10.1002/eqe.4290210402
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The response of adjacent buildings in city blocks to several strong earthquakes is analysed, taking into account the mutual collisions, or pounding, resulting from insufficient or non-existing separation distances. The buildings are idealized as lumped-mass, shear beam type, multi-degree-of-freedom (MDOF) systems with bilinear force-deformation characteristics and with bases supported on translational and rocking spring-dashpots. Collisions between adjacent masses can occur at any level and are simulated by means of viscoelastic impact elements. Using five real earthquake motions the effects of the following factors are investigated: building configuration and relative size, seismic separation distance and impact element properties. It is found that pounding can cause high overstresses, mainly when the colliding buildings have significantly different heights, periods or masses. This suggests a possibility for introducing a set of conditions into the codes, combined with some special measures, as an alternative to the seismic separation requirement.
引用
收藏
页码:289 / 302
页数:14
相关论文
共 50 条
  • [31] EARTHQUAKE-INDUCED LATERAL-TORSIONAL POUNDING BETWEEN THREE ADJACENT STRUCTURES
    Fiore, Alessandra
    Monaco, Pietro
    FIB SYMPOSIUM PRAGUE 2011: CONCRETE ENGINEERING FOR EXCELLENCE AND EFFICIENCY, VOLS 1 AND 2, 2011, : 851 - +
  • [32] Seismic pounding between adjacent buildings of unequal floor height
    Zou, Lihua
    Li, Liangfeng
    Huang, Jianqiang
    Huang, Kai
    JOURNAL OF VIBROENGINEERING, 2014, 16 (06) : 2756 - 2767
  • [33] Effective Equations for the Optimum Seismic Gap Preventing Earthquake-Induced Pounding between Adjacent Buildings Founded on Different Soil Types
    Miari, Mahmoud
    Jankowski, Robert
    APPLIED SCIENCES-BASEL, 2023, 13 (17):
  • [34] Earthquake-induced pounding between the main buildings of the "Quinto Orazio Flacco" school
    Fiore, Alessandra
    Monaco, Pietro
    EARTHQUAKES AND STRUCTURES, 2010, 1 (04) : 371 - 390
  • [35] Simulation of the earthquake-induced pounding of seismically isolated buildings
    Komodromos, Petros
    COMPUTERS & STRUCTURES, 2008, 86 (7-8) : 618 - 626
  • [36] Earthquake induced pounding in friction varying base isolated buildings
    Agarwal, V. K.
    Niedzwecki, J. M.
    van de Lindt, J. W.
    ENGINEERING STRUCTURES, 2007, 29 (11) : 2825 - 2832
  • [37] Recent Development in Analytical Models for Earthquake-Induced Pounding between Adjacent Bridge Structures
    Gao, Yufeng
    Pu, Qianhui
    Shi, Zhou
    ADVANCES IN STRUCTURES, PTS 1-5, 2011, 163-167 : 4244 - 4250
  • [38] Investigating the effect of pounding for inelastic base isolated adjacent buildings under earthquake excitations
    Uz, M. E.
    Hadi, M. N. S.
    INCORPORATING SUSTAINABLE PRACTICE IN MECHANICS OF STRUCTURES AND MATERIALS, 2011, : 329 - 334
  • [39] ANALYSIS OF EARTHQUAKE-INDUCED POUNDING FOR TWO ADJACENT SDOF SYSTEMS
    Zhai, Chang-Hai
    Jiang, Shan
    Li, Shuang
    Wu, Ying-Qiang
    Xie, Li-Li
    PROCEEDINGS OF THE ELEVENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOL I AND II, 2010, : 1833 - 1838
  • [40] Earthquake-induced pounding between equal height buildings with substantially different dynamic properties
    Jankowski, Robert
    ENGINEERING STRUCTURES, 2008, 30 (10) : 2818 - 2829