MEASUREMENTS OF ENDOMETRIAL BLOOD-FLOW IN ANESTHETIZED EWES BY XE-133 CLEARANCE AND MICROSPHERE TECHNIQUES

被引:4
|
作者
FRASER, IS
BROWN, BW
MATTNER, PE
HUTTON, BF
机构
[1] CSIRO,DIV ANIM PROD,BLACKTOWN,NSW 2148,AUSTRALIA
[2] ROYAL PRINCE ALFRED HOSP,DEPT NUCL MED,CAMPERDOWN,NSW 2050,AUSTRALIA
来源
QUARTERLY JOURNAL OF EXPERIMENTAL PHYSIOLOGY AND COGNATE MEDICAL SCIENCES | 1982年 / 67卷 / 04期
关键词
D O I
10.1113/expphysiol.1982.sp002673
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
引用
收藏
页码:531 / 535
页数:5
相关论文
共 50 条
  • [31] EVALUATION OF THE XE-133 CLEARANCE METHOD FOR INDIRECT PLACENTAL BLOOD-FLOW DETERMINATION
    SCHMITT, RM
    KURZ, CS
    GIESE, WW
    PLACENTA, 1984, 5 (06) : 495 - 511
  • [32] EXPERIMENTS TO DEMONSTRATE RELATIONSHIP BETWEEN XE-133 CLEARANCE AND RENAL BLOOD-FLOW
    DEVONSHIRE, RE
    NASHAT, FS
    TAPPIN, JW
    JOURNAL OF PHYSIOLOGY-LONDON, 1975, 247 (01): : P9 - P11
  • [33] DETERMINATION OF CAPILLARY BLOOD-FLOW IN IRRADIATED MOUSE TISSUES - XE-133 CLEARANCE
    CHRISTIAN, EJ
    STEARNER, SP
    RADIATION RESEARCH, 1973, 55 (03) : 588 - 588
  • [34] CADMIUM TELLURIDE XE-133 CLEARANCE DETECTOR FOR MUSCLE BLOOD-FLOW STUDIES
    CERRETELLI, P
    BLAU, M
    PENDERGAST, D
    EISENHARDT, C
    RENNIE, DW
    STEINBACH, J
    ENTINE, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (01) : 620 - 623
  • [35] CHANGES IN BLOOD-FLOW OF GROWING EXPERIMENTAL TUMOR DETERMINED BY THE CLEARANCE OF XE-133
    SIRACKA, E
    PAPPOVA, N
    PIPA, V
    DURKOVSKY, J
    NEOPLASMA, 1979, 26 (02) : 173 - 177
  • [36] BLOOD-FLOW MEASUREMENTS AND THE PARTITION-COEFFICIENT OF XE-133 IN BONE
    LEACH, MO
    BELL, CMJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1982, 27 (11): : 1401 - 1403
  • [37] COMPARATIVE-STUDY OF LIVER BLOOD-FLOW USING XE-133 CLEARANCE AND ELECTROMAGNETIC FLOWMETER MEASUREMENTS
    MATHIE, RT
    HUGHES, RL
    HARPER, AM
    BLUMGART, LH
    ACTA CHIRURGICA SCANDINAVICA, 1978, 144 (7-8): : 481 - 485
  • [38] INTERSCAPULAR BROWN ADIPOSE-TISSUE BLOOD-FLOW IN THE RAT - DETERMINATION WITH XE-133 CLEARANCE COMPARED TO THE MICROSPHERE METHOD
    ASTRUP, A
    BULOW, J
    MADSEN, J
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1984, 401 (04): : 414 - 417
  • [39] ENDOMETRIAL BLOOD-FLOW MEASURED BY XE-133 CLEARANCE IN WOMEN WITH NORMAL MENSTRUAL CYCLES AND DYSFUNCTIONAL UTERINE BLEEDING
    FRASER, IS
    MCCARRON, G
    HUTTON, B
    MACEY, D
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1987, 156 (01) : 158 - 166
  • [40] HETEROGENEITY OF CAPILLARY BLOOD-FLOW IN SKELETAL-MUSCLE - EVIDENCE FROM LOCAL XE-133 CLEARANCE AND MICROSPHERE TRAPPING
    MARCONI, C
    CERRETELLI, P
    PENDERGAST, D
    MEYER, M
    HEISLER, N
    PIIPER, J
    ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY, 1984, 169 : 487 - 488