INFLUENCE OF COOLING TIME ON THE INTERNAL ENERGY OF IONS SUBJECTED TO RESONANCE EXCITATION IN A QUADRUPOLE ION-TRAP

被引:22
|
作者
LIERE, P
BLASCO, T
MARCH, RE
TABET, JC
机构
[1] UNIV PARIS 06,CHIM ORGAN STRUCT LAB,ERS 73,PARIS 05,FRANCE
[2] TRENT UNIV,DEPT CHEM,PETERBOROUGH,ON K9J 7B8,CANADA
关键词
D O I
10.1002/rcm.1290081209
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study demonstrates the influence of cooling time, applied prior to (and after) resonance excitation, on the internal energy carried by ions subjected to tickle excitation. Competitive fragmentations of ionized butylbenzene have been used to estimate the internal energy average transferred during collision processes. Two competitive effects have been observed by using a delay time before tickle: kinetic energy relaxation (up to 15 ms) related to an internal energy decrease effect and, at higher cooling time values, collisional excitation with helium buffer gas allows one to increase the internal energy of precursor ions.
引用
收藏
页码:953 / 956
页数:4
相关论文
共 50 条
  • [22] NONDESTRUCTIVE DETECTION OF IONS IN A QUADRUPOLE ION-TRAP USING A DC PULSE TO FORCE COHERENT ION MOTION - A SIMULATION STUDY
    COOKS, RG
    CLEVEN, CD
    HORN, LA
    NAPPI, M
    WEIL, C
    SONI, MH
    JULIAN, RK
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1995, 146 : 147 - 163
  • [23] Beam cooling at the low-energy-beam and ion-trap facility at NSCL/MSU
    Bollen, G
    Schwarz, S
    Davies, D
    Lofy, P
    Morrissey, D
    Ringle, R
    Schury, P
    Sun, T
    Weissman, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 532 (1-2): : 203 - 209
  • [24] HOW TO ACHIEVE A WELL-DEFINED RESONANCE EXCITATION IN ION-TRAP MASS-SPECTROMETRY
    VETTORI, U
    TRALDI, P
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (04) : 312 - 314
  • [25] FILTERED NOISE FIELD SIGNALS FOR MASS-SELECTIVE ACCUMULATION OF EXTERNALLY FORMED IONS IN A QUADRUPOLE ION-TRAP
    GOERINGER, DE
    ASANO, KG
    MCLUCKEY, SA
    HOEKMAN, D
    STILLER, SW
    ANALYTICAL CHEMISTRY, 1994, 66 (03) : 313 - 318
  • [26] COMPUTED ENERGY PROPERTIES OF IONS STORED IN A QUADRUPOLE RF TRAP AND COOLED BY SIDEBAND EXCITATION
    ANDRE, J
    TEBOUL, A
    VEDEL, F
    JOURNAL DE PHYSIQUE LETTRES, 1984, 45 (01): : L1 - L10
  • [27] RESPONSE-TIME OF IONS TO COLLISIONAL ACTIVATION IN ION-TRAP MASS-SPECTROMETRY
    PARADISI, C
    TRALDI, P
    VETTORI, U
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (07) : 690 - 692
  • [28] Characterization of cardiolipin as the sodiated ions by positive-ion electrospray ionization with multiple stage quadrupole ion-trap mass spectrometry
    Hsu, Fong-Fu
    Turk, John
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2006, 17 (08) : 1146 - 1157
  • [29] THE INFLUENCE OF COLLISIONAL COOLING ON BOUNDARY-ACTIVATED DECOMPOSITION IN AN ION-TRAP MASS-SPECTROMETER
    MARCH, RE
    LONDRY, FA
    FONTANA, S
    CATINELLA, S
    TRALDI, P
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (10) : 929 - 934
  • [30] Comparison of quadrupole time-of-flight, triple quadrupole, and ion-trap mass spectrometry/mass spectrometry for the analysis of emerging contaminants
    Thurman, EM
    Ferrer, I
    LIQUID CHROMATOGRAPHY/MASS SPECTROMETRY, MS/MS AND TIME-OF-FLIGHT MS, 2003, 850 : 14 - 31