Acceptance criteria for flattening filter-free photon beam from standard medical electron linear accelerator: AERB task group recommendations

被引:14
|
作者
Sahani, G. [1 ]
Sharma, S. D. [2 ]
Sharma, P. K. Dash
Deshpande, D. D. [3 ]
Negi, P. S. [5 ]
Sathianarayanan, V. K. [4 ]
Rath, G. K. [6 ]
机构
[1] Atom Energy Regulatory Board, Radiol Safety Div, Bombay, Maharashtra, India
[2] CTCRS, Bhabha Atom Res Ctr, Radiol Phys & Advisory Div, Bombay, Maharashtra, India
[3] Tata Mem Hosp, Dept Med Phys, Bombay, Maharashtra, India
[4] Ruby Hall Clin, Dept Radiotherapy, Pune, Maharashtra, India
[5] Delhi State Canc Inst, Dept Med Phys, Delhi, India
[6] All India Inst Med Sci, Dr BR Ambedkar Inst Rotary Canc Hosp, New Delhi, India
关键词
Flattening filter free; medical accelerator; photon beam; quality assurance; unflat photo beam;
D O I
10.4103/0971-6203.144482
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Medical electron linear accelerators with the capability of generating unflat photon (flattening filter-free, FFF) beams are also available commercially for clinical applications in radiotherapy. However, the beam characteristics evaluation criteria and parameters are not yet available for such photon beams. Atomic Energy Regulatory Board (AERB) of India constituted a Task Group comprising experts from regulatory agency, advisory body/research and technical institutions, and clinical radiotherapy centers in the country to evolve and recommend the acceptance criteria for the flattening filter-free (FFF) photon beams. The Task Group thoroughly reviewed the literature and inputs of the manufactures/suppliers of the FFF linac and recommended a set of dosimetry parameters for evaluating the characteristics of the unflat photon beam. The recommendations included the evaluation of quality index, degree of unflatness, difference in percentage surface dose between flat and unflat photon beams, percentage depth dose at 10 cm depth, off-axis-ratios and radiation beam penumbra. The recommended parameters were evaluated for FFF photon beams generated by three different models of the linac, and it was observed that recommended evaluation methods are simple and easy to be implemented with the existing dosimetry and quality assurance infrastructure of the linac facilities of the radiotherapy departments. Recommendations were also made for periodic quality control check of the unflat photon beams and constancy evaluation in the beam characteristics.
引用
收藏
页码:206 / 211
页数:6
相关论文
共 6 条
  • [1] Commissioning of portal dosimetry using a novel method for flattening filter-free photon beam in a nontrue beam linear accelerator
    Gandhi, Arun
    Vellaiyan, Subramani
    Subramanian, V. S.
    Shanmugam, Thirumalaiswamy
    Murugesan, Kathirvel
    Subramanian, Kala
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (01) : 223 - 230
  • [2] COMMISSIONING OF PHOTON BEAMS OF A FLATTENING FILTER-FREE LINEAR ACCELERATOR AND THE ACCURACY OF BEAM MODELING USING AN ANISOTROPIC ANALYTICAL ALGORITHM
    Hrbacek, Jan
    Lang, Stephanie
    Kloeck, Stephan
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (04): : 1228 - 1237
  • [3] Dosimetric properties of equivalent-quality flattening filter-free (FFF) and flattened photon beams of Versa HD linear accelerator
    Meshram, Mukesh N.
    Pramanik, Srimanta
    Ranjith, C. P.
    Gopal, Saravana K.
    Dobhal, Rishabh
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03): : 358 - 370
  • [4] The Use of Photon Beams of a Flattening Filter-free Linear Accelerator for Hypofractionated Volumetric Modulated Arc Therapy in Localized Prostate Cancer
    Zwahlen, Daniel R.
    Lang, Stephanie
    Hrbacek, Jan
    Glanzmann, Christoph
    Kloeck, Stephan
    Najafi, Yousef
    Streller, Tino
    Studer, Gabriela
    Zaugg, Kathrin
    Luetolf, Urs M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (05): : 1655 - 1660
  • [5] Development of a dose-rate dosimeter using a silicon photodiode for a medical linear accelerator in a 10 MV flattening filter-free mode
    Yamaguchi, Satoshi
    Ariga, Hisanori
    Yoshioka, Kunihiro
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (05):
  • [6] Comparison of Measured and Monte Carlo Calculated Dose Distributions from Indigenously Developed 6 MV Flattening Filter Free Medical Linear Accelerator
    Mishra, Bibekananda
    Mishra, Subhalaxmi
    Selvam, T. Palani
    Chavan, S. T.
    Pethe, S. N.
    JOURNAL OF MEDICAL PHYSICS, 2018, 43 (03) : 162 - 167