POLLUTED INSULATOR FLASHOVER MODEL FOR AC VOLTAGE

被引:73
|
作者
GHOSH, PS
CHATTERJEE, N
机构
[1] Department of Electrical Engineering, High Tension Laboratory, Jadavpur University, Calcutta
关键词
D O I
10.1109/94.368688
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Considerable theoretical and experimental research on polluted insulators is yet to yield a perfect generalized mathematical model which can predict accurately critical flashover voltages and currents. In this paper an ac model has been proposed especially applicable to static arcs. The salient features of the proposed model is that it takes into account the appropriate selection of are constants for different chemical nature of the pollutants. The computed results closely follow the experimental curves and can predict rms value of critical flashover voltages with a mean absolute error (MAE) of < 4%. The validity of the model was verified by comparing the computed results of rms critical flashover voltages and currents against experimental and theoretical data of other researchers for a number of practical insulator of different geometries and good agreement has been obtained.
引用
收藏
页码:128 / 136
页数:9
相关论文
共 50 条
  • [31] Using corrected criteria to model flashover voltage of polluted insulators
    Ziari, Iman
    Gholami, Ahmad
    Jalilian, Alireza
    First International Power & Energy Conference (PECon 2006), Proceedings, 2006, : 602 - 606
  • [32] Dynamic model to predict AC critical flashover voltage of nonuniformly polluted insulators under thermal ionization conditions
    Shahabi, Saeed
    Gholami, Ahmad
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2017, 25 (03) : 2322 - 2335
  • [33] Adaptive Neuro-Fuzzy Inference System Application of Flashover Voltage of High-Voltage Polluted Insulator
    Belkebir, Amel
    Bourek, Yacine
    Benguesmia, Hani
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2024, 19 (06) : 3839 - 3849
  • [34] Flashover voltage and time prediction of polluted silicone rubber insulator based on artificial neural networks
    Mohsenzadeh, Mohammad Mahdi
    Hasanzadeh, Saeed
    Sezavar, Hamid Reza
    Samimi, Mohammad Hamed
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 221
  • [35] Experimental Study of the Flashover Process and the Leakage Current on the Surface of High Voltage Insulator Under AC Voltage
    Benguesmia, Hani
    Bakri, Badis
    Mekkas, Yasmine
    M'ziou, Nassima
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2024, : 2553 - 2567
  • [36] RELATION BETWEEN ac FLASHOVER VOLTAGE AND VOLTAGE BUILD-UP RATE ON RECTANGULAR POLLUTED SURFACES.
    Sato, Masashi
    Kaga, Akio
    Akagami, Hideo
    Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi), 1984, 104 (02): : 11 - 18
  • [37] Study on AC flashover performance and discharge process of polluted and iced IEC standard suspension insulator string
    Jiang, Xingliang
    Wang, Shaohua
    Zhang, Zhijin
    Xie, Shujiao
    Wang, Yan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (01) : 472 - 480
  • [38] Influence of a Grading Ring on AC Flashover Voltage of an EHV Post Insulator Covered with Ice
    Volat, C.
    Farzaneh, F.
    Akkal, H.
    CEIDP: 2009 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2009, : 399 - 402
  • [39] Influence of Surface Charge on Flashover Voltage of Gas Insulated Substation Basin Insulator under AC and DC Voltage
    Qi B.
    Gao C.
    Zhao L.
    Li C.
    Tu Y.
    Gaodianya Jishu/High Voltage Engineering, 2017, 43 (03): : 915 - 922
  • [40] AC Flashover: An Analysis with Influence of the Pollution, Potential and Electric Field Distribution on High Voltage Insulator
    Benguesmia, Hani
    M'ziou, Nassima
    Boubakeur, Ahmed
    MULTIPHYSICS MODELLING AND SIMULATION FOR SYSTEMS DESIGN AND MONITORING, 2015, 2 : 269 - 279