POLLUTED INSULATOR FLASHOVER MODEL FOR AC VOLTAGE

被引:73
|
作者
GHOSH, PS
CHATTERJEE, N
机构
[1] Department of Electrical Engineering, High Tension Laboratory, Jadavpur University, Calcutta
关键词
D O I
10.1109/94.368688
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Considerable theoretical and experimental research on polluted insulators is yet to yield a perfect generalized mathematical model which can predict accurately critical flashover voltages and currents. In this paper an ac model has been proposed especially applicable to static arcs. The salient features of the proposed model is that it takes into account the appropriate selection of are constants for different chemical nature of the pollutants. The computed results closely follow the experimental curves and can predict rms value of critical flashover voltages with a mean absolute error (MAE) of < 4%. The validity of the model was verified by comparing the computed results of rms critical flashover voltages and currents against experimental and theoretical data of other researchers for a number of practical insulator of different geometries and good agreement has been obtained.
引用
收藏
页码:128 / 136
页数:9
相关论文
共 50 条
  • [21] Effect of insulator diameter on AC flashover voltage of an ice-covered insulator string
    Farzaneh, M
    Zhang, J
    Volat, C
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2006, 13 (02) : 264 - 271
  • [22] Electrical Circuit Flashover Model of Polluted Insulators under AC Voltage Based on the Arc Root Voltage Gradient Criterion
    Yang, Qing
    Wang, Rui
    Sima, Wenxia
    Jiang, Chilong
    Lan, Xing
    Zahn, Markus
    ENERGIES, 2012, 5 (03): : 752 - 769
  • [23] Predictive dynamic model of the leakage current and flashover voltage of discontinuously polluted insulators under ac voltage: experimental validation
    Dhahbi-Megriche, N.
    Beroual, A.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2007, 40 (24) : 7782 - 7786
  • [24] AC flashover performance and mechanism of polluted and iced IEC standard suspension insulator string
    Sun, CX
    Jiang, XL
    Shu, LC
    Lu, Z
    Chen, MY
    PROCEEDINGS OF THE THIRTEENTH (2003) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL 1, 2003, : 409 - 415
  • [25] Effect of Ultrasonic Fog on AC Flashover Voltage of Polluted Porcelain and Glass Insulators
    Jiang, Xingliang
    Dong, Bingbing
    Hu, Qin
    Yin, Fanghui
    Xiang, Ze
    Shu, Lichun
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (02) : 429 - 434
  • [26] A Novel Forecasting Model of Contaminated Insulator Flashover Voltage
    Xu Jianyuan
    Teng Yun
    Lin Xin
    ICIEA: 2009 4TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-6, 2009, : 2967 - 2971
  • [27] DC pollution flashover model and its validation of polluted insulator strings
    Zhang, Zhijin
    Jiang, Xingliang
    Sun, Caixin
    Hu, Jianlin
    Yuan, Jihe
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2009, 24 (04): : 36 - 41
  • [28] EFFECT OF INSULATOR PROFILES ON DC FLASHOVER VOLTAGE UNDER POLLUTED CONDITIONS - A STUDY USING A DYNAMIC ARC MODEL
    SUNDARARAJAN, R
    GORUR, RS
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1994, 1 (01) : 124 - 132
  • [29] Measurement and evaluation of the flashover voltage on polluted cap and pin insulator: An experimental and theoretical study
    Belhouchet, Khaled
    Ghadbane, Ismail
    Zemmit, Abderrahim
    Ouchen, Lyamine
    Zorig, Assam
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 236
  • [30] Using correced criteria to model flashover voltage of polluted insulators
    Ziari, Iman
    Gholami, Ahmad
    Jalilian, Afireza
    PROCEEDINGS OF THE 41ST INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1 AND 2, 2006, : 262 - 266