ULTRAVIOLET-RADIATION AND THE CONTROL OF AIRBORNE CONTAMINATION IN THE OPERATING-ROOM

被引:36
|
作者
LIDWELL, OM
机构
关键词
ULTRAVIOLET; OPERATING ROOM; AIRBORNE BACTERIA;
D O I
10.1016/0195-6701(94)90088-4
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Ultraviolet irradiation has been employed in operating rooms for more than half a century in attempts to reduce airborne bacterial contamination. Safety considerations have limited its intensity to 25-30 muw cm-2 and at this level no more than a fourfold reduction has resulted. In recent studies intensities up to 300 muw cm-2 have been used without untoward effects, and, at the highest intensity, contamination as low as that obtained with ultraclean air ventilation systems was obtained. However this was only achieved in an operating room where the level of airborne contamination before the introduction of the radiation was already much lower (around one-fifth) than that usually observed, and the reduction attributable to the radiation was still only about 12-fold.
引用
收藏
页码:245 / 248
页数:4
相关论文
共 50 条
  • [1] Improvement of the Indoor Environment and Airborne Contamination Control in an Operating Room
    Wang, Fu Jen
    Yau, Yat Huang
    Wen Bin Ng
    Lai, Chi Ming
    ADVANCES IN CIVIL ENGINEERING, PTS 1-6, 2011, 255-260 : 1532 - 1536
  • [2] LIGHT HAZARDS IN THE OPERATING-ROOM
    COWAN, CL
    JOURNAL OF THE NATIONAL MEDICAL ASSOCIATION, 1992, 84 (05) : 425 - 429
  • [3] A HOSPITAL ADMINISTRATORS VIEW OF THE OPERATING-ROOM
    JEON, AA
    JOURNAL OF CLINICAL ANESTHESIA, 1995, 7 (07) : 585 - 588
  • [4] INFLUENCE OF GUIDELINES OF THE FEDERAL HEALTH AUTHORITIES ON ENVIRONMENTAL CONTAMINATION AT A GENERAL EMERGENCY DEPARTMENT AND IN AN ORTHOPEDIC OPERATING-ROOM
    HUBNER, J
    HABEL, H
    FARTHMANN, EH
    REICHELT, A
    DASCHNER, F
    CHIRURG, 1991, 62 (12): : 871 - 874
  • [5] A MODEL OF THE DIFFUSE ULTRAVIOLET-RADIATION FIELD
    MURTHY, J
    HENRY, RC
    ASTROPHYSICAL JOURNAL, 1995, 448 (02): : 848 - 857
  • [6] Investigation of Airflow Distribution and Contamination Control with Different Schemes in an Operating Room
    Wang, Fujen
    Permana, Indra
    Rakshit, Dibakar
    Prasetyo, Bowo Yuli
    ATMOSPHERE, 2021, 12 (12)
  • [7] USE OF BUILT-IN SCREEN SLIDE VIEWER IN THE OPERATING-ROOM
    JACKSON, IT
    FUKUTA, K
    AVERY, CM
    EUROPEAN JOURNAL OF PLASTIC SURGERY, 1994, 17 (01) : 51 - 51
  • [8] Numerical simulation on a horizontal airflow for airborne particles control in hospital operating room
    Liu, Junjie
    Wang, Haidong
    Wen, Wenyong
    BUILDING AND ENVIRONMENT, 2009, 44 (11) : 2284 - 2289
  • [9] Numerical simulation on a horizontal airflow for airborne particles control in hospital operating room
    Liu, Junjie
    Wang, Haidong
    Wen, Wenyong
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 1283 - 1290
  • [10] NOISE-POLLUTION IN THE OPERATING-ROOM - A HAZARD TO SURGEONS, PERSONNEL, AND PATIENTS
    RAY, CD
    LEVINSON, R
    JOURNAL OF SPINAL DISORDERS, 1992, 5 (04): : 485 - 488