DAMAGE TO MACOR GLASS-CERAMIC FROM HIGH-DOSE 14 MEV NEUTRONS

被引:9
作者
COGHLAN, WA [1 ]
CLINARD, FW [1 ]
机构
[1] UNIV CALIF LOS ALAMOS SCI LAB,DIV MAT SCI & TECHNOL,LOS ALAMOS,NM 87545
关键词
D O I
10.1016/0022-3115(91)90107-I
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Macor machinable glass-ceramic was irradiated to fluences up to 1 x 10(23) 14 MeV n/m2 at room temperature. Post-irradiation measurements were carried ut to determine changes in high-frequency electrical conductivity, hardness, and density. It was found that neutron damage caused slight increases in conductivity and hardness. The major change noted was in density, where a fluence of 4 x 10(22) n/m2 caused swelling of 1.55 vol% while a dose of 1 x 10(23) n/m2 resulted in a lower swelling value (0.82 vol%). This unusual behavior is explained by a model involving expansion of the mica phase of Macor and contraction of the glassy phase. Implications of the present results for engineering performance of Macor at these and higher fluences are discussed.
引用
收藏
页码:391 / 394
页数:4
相关论文
共 10 条