首页
学术期刊
论文检测
AIGC检测
热点
更多
数据
MEASUREMENT OF CARDIAC-OUTPUT BY THE THERMODILUTION METHOD DURING LEFT THORACOTOMY IN THE LATERAL POSITION IN THE DOG
被引:4
作者
:
LANDAIS, A
论文数:
0
引用数:
0
h-index:
0
机构:
HOP ST JOSEPH, F-75674 PARIS 14, FRANCE
LANDAIS, A
MORIN, JP
论文数:
0
引用数:
0
h-index:
0
机构:
HOP ST JOSEPH, F-75674 PARIS 14, FRANCE
MORIN, JP
ROCHE, A
论文数:
0
引用数:
0
h-index:
0
机构:
HOP ST JOSEPH, F-75674 PARIS 14, FRANCE
ROCHE, A
CORNEC, C
论文数:
0
引用数:
0
h-index:
0
机构:
HOP ST JOSEPH, F-75674 PARIS 14, FRANCE
CORNEC, C
SANSOY, N
论文数:
0
引用数:
0
h-index:
0
机构:
HOP ST JOSEPH, F-75674 PARIS 14, FRANCE
SANSOY, N
机构
:
[1]
HOP ST JOSEPH, F-75674 PARIS 14, FRANCE
[2]
CTR MED CHIRURG PORT CHOISY, PARIS, FRANCE
来源
:
ACTA ANAESTHESIOLOGICA SCANDINAVICA
|
1990年
/ 34卷
/ 02期
关键词
:
Cardiac output;
dogs;
lateral position;
thermodilution;
thoracotomy;
D O I
:
10.1111/j.1399-6576.1990.tb03061.x
中图分类号
:
R614 [麻醉学];
学科分类号
:
100217 ;
摘要
:
The validity of cardiac output measurement by thermodilution in the lateral position during thoracotomy was assessed. Three balloon thermodilution Swan‐Ganz catheters were placed in the pulmonary artery trunk and the right and left pulmonary arteries in 12 mongrel dogs, after left thoracotomy had been performed. Cardiac output was measured simultaneously from two of the three sites. The cardiac output measurements show no significant difference related to the location of the cathether extremities: the mean cardiac index was found to be 2.164 ± 0.448 1/min/m2 from the pulmonary artery trunk, 2.127 ± 0.404 1/min/m2 from the left branch and 2.116 ± 0.421 1/min/m2 from the right branch. It is concluded that the measurement of cardiac output during left thoracotomy is valid, whether the thermistor is situated in the pulmonary artery trunk or in a main branch to either the dependent or non‐dependent lung. © 1990 Acta Anaesthesiologica Scandinavica Fonden
引用
收藏
页码:158 / 161
页数:4
相关论文
共 5 条
[1]
SEMINAR ON CLINICAL APPLICATION OF TECHNIQUES TO MEASURE BLOOD-FLOW IN MAN .2. MEASUREMENT OF BLOOD-FLOW BY THERMODILUTION
[J].
GANZ, W
论文数:
0
引用数:
0
h-index:
0
GANZ, W
;
SWAN, HJC
论文数:
0
引用数:
0
h-index:
0
SWAN, HJC
.
AMERICAN JOURNAL OF CARDIOLOGY,
1972,
29
(02)
:241
-+
[2]
NEW TECHNIQUE FOR MEASUREMENT OF CARDIAC OUTPUT BY THERMODILUTION IN MAN
[J].
GANZ, W
论文数:
0
引用数:
0
h-index:
0
GANZ, W
;
DONOSO, R
论文数:
0
引用数:
0
h-index:
0
DONOSO, R
;
MARCUS, HS
论文数:
0
引用数:
0
h-index:
0
MARCUS, HS
;
FORRESTER, JS
论文数:
0
引用数:
0
h-index:
0
FORRESTER, JS
;
SWAN, HJC
论文数:
0
引用数:
0
h-index:
0
SWAN, HJC
.
AMERICAN JOURNAL OF CARDIOLOGY,
1971,
27
(04)
:392
-+
[3]
EFFECT OF CATHETER POSITION ON THERMODILUTION CARDIAC-OUTPUT DURING CONTINUOUS POSITIVE-PRESSURE VENTILATION
[J].
HASAN, FM
论文数:
0
引用数:
0
h-index:
0
机构:
BROWN UNIV, DIV BIOL & MED, PROVIDENCE, RI 02912 USA
BROWN UNIV, DIV BIOL & MED, PROVIDENCE, RI 02912 USA
HASAN, FM
;
MALANGA, A
论文数:
0
引用数:
0
h-index:
0
机构:
BROWN UNIV, DIV BIOL & MED, PROVIDENCE, RI 02912 USA
BROWN UNIV, DIV BIOL & MED, PROVIDENCE, RI 02912 USA
MALANGA, A
;
CORRAO, WM
论文数:
0
引用数:
0
h-index:
0
机构:
BROWN UNIV, DIV BIOL & MED, PROVIDENCE, RI 02912 USA
BROWN UNIV, DIV BIOL & MED, PROVIDENCE, RI 02912 USA
CORRAO, WM
;
BRAMAN, SS
论文数:
0
引用数:
0
h-index:
0
机构:
BROWN UNIV, DIV BIOL & MED, PROVIDENCE, RI 02912 USA
BROWN UNIV, DIV BIOL & MED, PROVIDENCE, RI 02912 USA
BRAMAN, SS
.
CRITICAL CARE MEDICINE,
1984,
12
(04)
:387
-390
[4]
KAPLAN J, 1982, THORACIC ANESTHESIA, P278
[5]
THERMODILUTION CARDIAC-OUTPUT - CRITICAL ANALYSIS AND REVIEW OF THE LITERATURE
[J].
LEVETT, JM
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV CHICAGO, PRITZKER SCH MED, DEPT SURG, CHICAGO, IL 60637 USA
UNIV CHICAGO, PRITZKER SCH MED, DEPT SURG, CHICAGO, IL 60637 USA
LEVETT, JM
;
REPLOGLE, RL
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV CHICAGO, PRITZKER SCH MED, DEPT SURG, CHICAGO, IL 60637 USA
UNIV CHICAGO, PRITZKER SCH MED, DEPT SURG, CHICAGO, IL 60637 USA
REPLOGLE, RL
.
JOURNAL OF SURGICAL RESEARCH,
1979,
27
(06)
:392
-404
←
1
→
共 5 条
[1]
SEMINAR ON CLINICAL APPLICATION OF TECHNIQUES TO MEASURE BLOOD-FLOW IN MAN .2. MEASUREMENT OF BLOOD-FLOW BY THERMODILUTION
[J].
GANZ, W
论文数:
0
引用数:
0
h-index:
0
GANZ, W
;
SWAN, HJC
论文数:
0
引用数:
0
h-index:
0
SWAN, HJC
.
AMERICAN JOURNAL OF CARDIOLOGY,
1972,
29
(02)
:241
-+
[2]
NEW TECHNIQUE FOR MEASUREMENT OF CARDIAC OUTPUT BY THERMODILUTION IN MAN
[J].
GANZ, W
论文数:
0
引用数:
0
h-index:
0
GANZ, W
;
DONOSO, R
论文数:
0
引用数:
0
h-index:
0
DONOSO, R
;
MARCUS, HS
论文数:
0
引用数:
0
h-index:
0
MARCUS, HS
;
FORRESTER, JS
论文数:
0
引用数:
0
h-index:
0
FORRESTER, JS
;
SWAN, HJC
论文数:
0
引用数:
0
h-index:
0
SWAN, HJC
.
AMERICAN JOURNAL OF CARDIOLOGY,
1971,
27
(04)
:392
-+
[3]
EFFECT OF CATHETER POSITION ON THERMODILUTION CARDIAC-OUTPUT DURING CONTINUOUS POSITIVE-PRESSURE VENTILATION
[J].
HASAN, FM
论文数:
0
引用数:
0
h-index:
0
机构:
BROWN UNIV, DIV BIOL & MED, PROVIDENCE, RI 02912 USA
BROWN UNIV, DIV BIOL & MED, PROVIDENCE, RI 02912 USA
HASAN, FM
;
MALANGA, A
论文数:
0
引用数:
0
h-index:
0
机构:
BROWN UNIV, DIV BIOL & MED, PROVIDENCE, RI 02912 USA
BROWN UNIV, DIV BIOL & MED, PROVIDENCE, RI 02912 USA
MALANGA, A
;
CORRAO, WM
论文数:
0
引用数:
0
h-index:
0
机构:
BROWN UNIV, DIV BIOL & MED, PROVIDENCE, RI 02912 USA
BROWN UNIV, DIV BIOL & MED, PROVIDENCE, RI 02912 USA
CORRAO, WM
;
BRAMAN, SS
论文数:
0
引用数:
0
h-index:
0
机构:
BROWN UNIV, DIV BIOL & MED, PROVIDENCE, RI 02912 USA
BROWN UNIV, DIV BIOL & MED, PROVIDENCE, RI 02912 USA
BRAMAN, SS
.
CRITICAL CARE MEDICINE,
1984,
12
(04)
:387
-390
[4]
KAPLAN J, 1982, THORACIC ANESTHESIA, P278
[5]
THERMODILUTION CARDIAC-OUTPUT - CRITICAL ANALYSIS AND REVIEW OF THE LITERATURE
[J].
LEVETT, JM
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV CHICAGO, PRITZKER SCH MED, DEPT SURG, CHICAGO, IL 60637 USA
UNIV CHICAGO, PRITZKER SCH MED, DEPT SURG, CHICAGO, IL 60637 USA
LEVETT, JM
;
REPLOGLE, RL
论文数:
0
引用数:
0
h-index:
0
机构:
UNIV CHICAGO, PRITZKER SCH MED, DEPT SURG, CHICAGO, IL 60637 USA
UNIV CHICAGO, PRITZKER SCH MED, DEPT SURG, CHICAGO, IL 60637 USA
REPLOGLE, RL
.
JOURNAL OF SURGICAL RESEARCH,
1979,
27
(06)
:392
-404
←
1
→