DUAL ENERGY RADIOGRAPHY USING X-RAY-FILMS AND INTENSIFYING SCREENS

被引:3
|
作者
ZANANIRI, FAF [1 ]
SPELLER, RD [1 ]
机构
[1] UNIV COLL HOSP LONDON,DEPT MED PHYS & BIOENGN,WC1 LONDON,ENGLAND
来源
JOURNAL OF BIOMEDICAL ENGINEERING | 1990年 / 12卷 / 03期
关键词
Dual energy; intensifying screens; radiography;
D O I
10.1016/0141-5425(90)90048-R
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to investigate dual energy (DE) systems using X-ray films and intensifying screens as detecting media. This has been studied using both experimental methods and numerical modelling. Numerical methods were used to calculate energy losses due to K-fluourescent escape originating from the phosphors of the intensifying screens. This enabled the calculation of absorbed energy in screens. The method for screen selection and prediction of performance used the fact that detector response depends upon impinging X-ray energy. By equating the detector's absorbing characteristics to the resultant optical density (OD), an absorbed energy constant was calculated. These constants were used to predict OD for a given X-ray spectrum and hence simulation of detector characteristics. Experimental techniques were used to investigate sensitivity to chemical composition changes. These results compared favourably with computed values. It was demonstrated that although limitations exist, detector simulations are valid and X-ray film intensifying screen combinations make adequate DE detectors. © 1990.
引用
收藏
页码:239 / 247
页数:9
相关论文
共 50 条
  • [1] THE INTENSIFYING EFFECT OF METALLIC SCREENS ON THE SENSITIVITY OF X-RAY-FILMS AT 662 KEV
    NAVON, E
    BARNEA, G
    DICK, CE
    JOURNAL OF APPLIED PHYSICS, 1989, 65 (07) : 2852 - 2855
  • [2] INTENSIFYING EFFECT OF METALLIC SCREENS ON THE SENSITIVITY OF X-RAY-FILMS FOR 400-KV BREMSSTRAHLUNG PHOTONS
    NAVON, E
    DICK, CE
    BARNEA, G
    MEDICAL PHYSICS, 1991, 18 (02) : 299 - 304
  • [3] ASSESSMENT OF SIGNAL DETECTABILITY FOR CONVENTIONAL AND REVERSAL-PROCESSED MEDICAL X-RAY-FILMS OBTAINED WITHOUT INTENSIFYING SCREENS
    INATSU, H
    KARIYA, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1991, 30 (11A): : 2982 - 2987
  • [4] X-ray intensifying screens
    不详
    BRITISH MEDICAL JOURNAL, 1917, 1917 : 491 - 491
  • [5] Intensifying X-ray screens
    Blinov, N.N.
    Gorelik, F.G.
    Kon'kova, G.V.
    Meditsinskaya Tekhnika, 1993, (04): : 17 - 22
  • [6] ASSESSMENT OF IMAGE QUALITY OF NEGATIVE-PROCESSED AND REVERSAL-PROCESSED MEDICAL X-RAY-FILMS WITH INTENSIFYING SCREENS BY ENTROPY METHOD
    UCHIDA, S
    FUJITA, H
    INATSU, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1982, 21 (02): : 319 - 324
  • [7] TRIAGE OF X-RAY-FILMS
    DUKES, IK
    BRITISH MEDICAL JOURNAL, 1991, 302 (6783): : 1023 - 1024
  • [8] X-RAY-FILMS AND ASBESTOSIS
    DAVID, A
    CHEST, 1989, 96 (04) : 952 - 952
  • [9] COMMENT ON X-RAY-FILMS
    NORTON, LA
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1992, 102 (05) : A24 - A25
  • [10] TRIAGE OF X-RAY-FILMS
    RENWICK, IGH
    BRITISH MEDICAL JOURNAL, 1991, 302 (6786): : 1210 - 1210