Transpedicular screw fixation in the thoracic and lumbar spine with a novel cannulated polyaxial screw system

被引:0
作者
Weise, Lutz [1 ]
Suess, Olaf [1 ]
Picht, Thomas [1 ]
Kombos, Theodoros [1 ]
机构
[1] Charite, Neurochirurg Klin, Berlin, Germany
来源
MEDICAL DEVICES-EVIDENCE AND RESEARCH | 2008年 / 1卷
关键词
spinal instrumentation; pedicle screws; misplacement; pedicle wall perforation;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Transpedicular screws are commonly and successfully used for posterior fixation in spinal instability, but their insertion remains challenging. Even using navigation techniques, there is a misplacement rate of up to 11%. The aim of this study was to assess the accuracy of a novel pedicle screw system. Methods: Thoracic and lumbar fusions were performed on 67 consecutive patients for tumor, trauma, degenerative disease or infection. A total of 326 pedicular screws were placed using a novel wire-guided, cannulated, polyaxial screw system (XIA Precision((R)), Stryker). The accuracy of placement was assessed post operatively by CT scan, and the patients were followed-up clinically for a mean of 16 months. Results: The total medio-caudal pedicle wall perforation rate was 9.2% (30/326). In 19 of these 30 cases a cortical breakthrough of less than 2 mm occurred. The misplacement rate (defined as a perforation of 2 mm or more) was 3.37% (11/326). Three of these 11 screws needed surgical revision due to neurological symptoms or CSF leakage. There have been no screw breakages or dislocations over the follow up-period. Conclusion: We conclude that the use of this cannulated screw system for the placement of pedicle screws in the thoracic and lumbar spine is accurate and safe. The advantages of this technique include easy handling without a time-consuming set up. Considering the incidence of long-term screw breakage, further investigation with a longer follow-up period is necessary.
引用
收藏
页码:33 / 39
页数:7
相关论文
共 50 条
  • [31] In vitro flexibility of an experimental pedicle screw and plate instrumentation system on the porcine lumbar spine
    Lysack, JT
    Yen, D
    Dumas, GA
    MEDICAL ENGINEERING & PHYSICS, 2000, 22 (07) : 461 - 468
  • [32] Free hand pedicle screw placement in the thoracic spine: Is it safe?
    Kim, YJ
    Lenke, LG
    Bridwell, KH
    Cho, YSS
    Riew, KD
    SPINE, 2004, 29 (03) : 333 - 342
  • [33] Biomechanical arrangement of threaded and unthreaded portions providing holding power of transpedicular screw fixation
    Tsuang, Fon-Yih
    Chen, Chia-Hsien
    Wu, Lien-Chen
    Kuo, Yi-Jie
    Lin, Shang-Chih
    Chiang, Chang-Jung
    CLINICAL BIOMECHANICS, 2016, 39 : 71 - 76
  • [34] Improving the trajectory of transpedicular transdiscal lumbar screw fixation with a computer-assisted 3D-printed custom drill guide
    Shao, Zhen-Xuan
    Wang, Jian-Shun
    Lin, Zhong-Ke
    Ni, Wen-Fei
    Wang, Xiang-Yang
    Wu, Ai-Min
    PEERJ, 2017, 5
  • [35] Radiographic outcomes of transosseous intradiscal screw fixation in lumbar reconstruction-Imaging results of an experience with an alternative in fixation of the unexpectedly osteopenic spine
    Bednar, Drew A.
    Bednar, E. Demetra
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2018, 174 : 187 - 191
  • [36] COMPLICATIONS OF THE WILTSE PEDICLE SCREW FIXATION SYSTEM
    BLUMENTHAL, S
    GILL, K
    SPINE, 1993, 18 (13) : 1867 - 1871
  • [37] Reliability of axial landmarks for pedicle screw placement in the lower lumbar spine
    Robertson, PA
    Novotny, JE
    Grobler, LJ
    Abgai, JU
    SPINE, 1998, 23 (01) : 60 - 66
  • [38] The Reliability of the Ball-Tipped Probe for Detecting Pedicle Screw Tract Violations Prior to Instrumenting the Thoracic and Lumbar Spine
    Sedory, David M.
    Crawford, John J.
    Topp, Raymond F.
    SPINE, 2011, 36 (06) : E447 - E453
  • [39] Translaminar screw fixation in the subaxial pediatric cervical spine Technical note
    Jea, Andrew
    Johnson, Keyne K.
    Whitehead, William E.
    Luerssen, Thomas G.
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2008, 2 (06) : 386 - 390
  • [40] Screw augmentation for spinopelvic fixation in neuromuscular spine deformities: technical note
    Dubory, Arnaud
    Bachy, Manon
    Bouloussa, Houssam
    Courvoisier, Aurelien
    Morel, Baptiste
    Vialle, Raphael
    EUROPEAN SPINE JOURNAL, 2015, 24 (11) : 2580 - 2587