A new generation of absolute gravimeters

被引:394
作者
Niebauer, TM
Sasagawa, GS
Faller, JE
Hilt, R
Klopping, F
机构
[1] TABLE MT OBSERV,GEOSCI LAB,NOAA,LONGMONT,CO 80503
[2] UNIV COLORADO,NATL INST STAND & TECHNOL,JOINT INST LAB ASTROPHYS,BOULDER,CO 80309
[3] COLORADO COLL,DEPT PHYS,COLORADO SPRINGS,CO 80903
关键词
D O I
10.1088/0026-1394/32/3/004
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe the design improvements incorporated in a new generation of absolute gravimeters, the FG5. A vertically oriented (in-line) interferometer design is used to remove the influence of floor vibration and tilt on the optical path length. The interferometer uses an iodine-stabilized laser as a primary length standard, with circuitry for automatic peak detection and locking. The seismic isolation system is an active long-period seismometer (Super Spring). The new design has improved passive isolation and thermal drift characteristics over previous systems, Programming flexibility and control of the test mass trajectory have been improved. The computer system has also improved real-time analysis and system capability. The FG5 instrument has a higher level of robustness, reliability and ease of use. These design advances have led to an instrumental uncertainty estimate of 1,1 x 10(-8) m.s(-2) (1,0 mu Gal). Instrument agreement among nine similar devices is 1,8 mu Gal and observations under optimal conditions exhibit standard deviations of 5 mu Gal to 8 mu Gal.
引用
收藏
页码:159 / 180
页数:22
相关论文
共 50 条
  • [21] Microgravimetric measurements at the 1994 International Comparison of Absolute Gravimeters
    Becker, M
    Balestri, L
    Bartell, R
    Berrino, G
    Bonvalot, S
    Csapo, G
    Diament, M
    DErrico, M
    Gerstenecker, C
    Gagnon, C
    Jousset, P
    Kopaev, A
    Liard, J
    Marson, I
    Meurers, B
    Nowak, I
    Nakai, S
    Rehren, F
    Richter, B
    Schnull, M
    Somerhausen, A
    Spita, W
    Szatmari, G
    VanRuymbeke, M
    Wenzel, HG
    Wilmes, H
    Zucchi, M
    Zurn, W
    METROLOGIA, 1995, 32 (03) : 145 - 152
  • [22] Laser displacement interferometers with subnanometer resolution in absolute ballistic gravimeters
    Vitushkin, L. F.
    Orlov, O. A.
    Germak, A.
    D'Agostino, G.
    MEASUREMENT TECHNIQUES, 2012, 55 (03) : 221 - 228
  • [23] THE EFFECTIVE MEASUREMENT HEIGHT OF FREE-FALL ABSOLUTE GRAVIMETERS
    NIEBAUER, TM
    METROLOGIA, 1989, 26 (02) : 115 - 118
  • [24] Effects of impedance mismatch and coaxial cable length on absolute gravimeters
    Kren, Petr
    Palinkas, Vojtech
    Masika, Pavel
    Val'ko, Milos
    METROLOGIA, 2017, 54 (02) : 161 - 170
  • [25] A vibration correction method for free-fall absolute gravimeters
    Qian, J.
    Wang, G.
    Wu, K.
    Wang, L. J.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2018, 29 (02)
  • [26] TWO METHODS FOR DETERMINATION OF THE EFFECTIVEWAVENUMBER OF GAUSSIAN BEAMS IN ABSOLUTE GRAVIMETERS
    Kren, Petr
    Palinkas, Vojtech
    METROLOGY AND MEASUREMENT SYSTEMS, 2018, 25 (04) : 701 - 713
  • [27] High precision levelling supporting the International Comparison of Absolute Gravimeters
    Jiang, Z.
    Becker, M.
    Jousset, P.
    Coulomb, A.
    Tisserand, L.
    Boulanger, P.
    Lequin, D.
    Lhermitte, F.
    Houillon, J. L.
    Dupont, F.
    METROLOGIA, 2012, 49 (01) : 41 - 48
  • [28] Laser displacement interferometers with subnanometer resolution in absolute ballistic gravimeters
    L. F. Vitushkin
    O. A. Orlov
    A. Germak
    G. D’Agostino
    Measurement Techniques, 2012, 55 : 221 - 228
  • [29] The results of international metrological comparisons of absolute laser ballistic gravimeters
    Arnautov, G.P.
    Avtometriya, 2005, 41 (01): : 126 - 136
  • [30] Reducing the Time Consumption of Vibration Correction Methods for Absolute Gravimeters
    Guo, Meiying
    Wu, Kang
    Yao, Jiamin
    Wen, Yi
    Li, Zhenxing
    Wang, Lijun
    2019 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2019, : 1809 - 1813