A new generation of absolute gravimeters

被引:394
作者
Niebauer, TM
Sasagawa, GS
Faller, JE
Hilt, R
Klopping, F
机构
[1] TABLE MT OBSERV,GEOSCI LAB,NOAA,LONGMONT,CO 80503
[2] UNIV COLORADO,NATL INST STAND & TECHNOL,JOINT INST LAB ASTROPHYS,BOULDER,CO 80309
[3] COLORADO COLL,DEPT PHYS,COLORADO SPRINGS,CO 80903
关键词
D O I
10.1088/0026-1394/32/3/004
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe the design improvements incorporated in a new generation of absolute gravimeters, the FG5. A vertically oriented (in-line) interferometer design is used to remove the influence of floor vibration and tilt on the optical path length. The interferometer uses an iodine-stabilized laser as a primary length standard, with circuitry for automatic peak detection and locking. The seismic isolation system is an active long-period seismometer (Super Spring). The new design has improved passive isolation and thermal drift characteristics over previous systems, Programming flexibility and control of the test mass trajectory have been improved. The computer system has also improved real-time analysis and system capability. The FG5 instrument has a higher level of robustness, reliability and ease of use. These design advances have led to an instrumental uncertainty estimate of 1,1 x 10(-8) m.s(-2) (1,0 mu Gal). Instrument agreement among nine similar devices is 1,8 mu Gal and observations under optimal conditions exhibit standard deviations of 5 mu Gal to 8 mu Gal.
引用
收藏
页码:159 / 180
页数:22
相关论文
共 50 条
  • [1] Absolute ballistic gravimeters
    Vitushkin L.F.
    Gyroscopy and Navigation, 2015, 6 (4) : 254 - 259
  • [2] Development of new free-fall absolute gravimeters
    Rothleitner, Ch
    Svitlov, S.
    Merimeche, H.
    Hu, H.
    Wang, L. J.
    METROLOGIA, 2009, 46 (03) : 283 - 297
  • [3] The new A-10 absolute gravimeter at the 2001 International Comparison of Absolute Gravimeters
    Liard, J
    Gagnon, C
    METROLOGIA, 2002, 39 (05) : 477 - 483
  • [4] The diffraction correction for absolute gravimeters
    van Westrum, D
    Niebauer, TM
    METROLOGIA, 2003, 40 (05) : 258 - 263
  • [5] Evaluation of the precision of using absolute gravimeters to calibrate superconducting gravimeters
    Francis, O
    van Dam, T
    METROLOGIA, 2002, 39 (05) : 485 - 488
  • [6] REVIEW FOR THE INTERNATIONAL COMPARISON OF ABSOLUTE GRAVIMETERS
    LI, DX
    ACTA GEOPHYSICA SINICA, 1988, 31 (02): : 231 - 235
  • [7] Fourth International Comparison of Absolute Gravimeters
    Marson, I
    Faller, JE
    Cerutti, G
    DeMaria, P
    Chartier, JM
    Robertsson, L
    Vitushkin, L
    Friederich, J
    Krauterbluth, K
    Stizza, D
    Liard, J
    Gagnon, C
    Lothhammer, A
    Wilmes, H
    Makinen, J
    Murakami, M
    Rehren, F
    Schnull, M
    Ruess, D
    Sasagawa, GS
    METROLOGIA, 1995, 32 (03) : 137 - 144
  • [8] A VIBRATION COMPENSATION METHOD FOR ABSOLUTE GRAVIMETERS
    Wang, Guan
    Hu, Hua
    Wu, Kang
    Wang, Lijun
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2016, VOL. 4B, 2017,
  • [9] Verifying the precision of a new generation absolute gravimeter FG5 - Comparison with superconducting gravimeters and detection of oceanic loading tide
    Okubo, S
    Yoshida, S
    Sato, T
    Tamura, Y
    Imanishi, Y
    GEOPHYSICAL RESEARCH LETTERS, 1997, 24 (04) : 489 - 492
  • [10] Metrological traceability method for atomic absolute gravimeters
    Zhu, Dong
    Zhou, Yin
    Wu, Bin
    Weng, Kanxing
    Wang, Kainan
    Cheng, Bing
    Lin, Qiang
    APPLIED OPTICS, 2021, 60 (26) : 7910 - 7920