This article describes a procedure for performing routine three-color flow cytometric analysis for acute leukemia on lysed whole bone marrow preparations. This technique uses the combination of CD45 intensity and right-angle light scatter (RALS) to distinguish leukemic cells from normal lymphocytes, monocytes, neutrophils, eosinophils, and nucleated red blood cells. On this display, leukemic cells occupy a unique blast region characterized by intermediate CD45 density and low RALS, which, in normal marrows, contains less than 5% of the total cells. This approach was applied to 39 cases of acute leukemia and 8 cases of myelodysplasia or myeloproliferative disorders. The estimate of blasts by flow cytometric analysis was correlated highly with morphologic leukemic cell counts over a wide range. Moreover, the pattern seen on the CD45-RALS display was different for different French-American-British subtypes of leukemia, suggesting that this pattern might be useful for categorization. When CD45-peridin chlorophyll alpha protein was combined with other pairs of fluorescein isothiocyanate- and phycoerythrin-conjugated reagents, it was possible to set an analysis window on the leukemic blasts and display dual-parameter tie, green vs. red fluorescence) data regarding expression of two additional markers on the leukemic population. This gating strategy was superior to traditional forward-angle versus RALS displays in that it did a better job of isolating the leukemic cells analytically.
引用
收藏
页码:534 / 540
页数:7
相关论文
共 22 条
[1]   DETECTION OF LYMPHOCYTE SUBSETS USING 3-COLOR SINGLE-LASER FLOW-CYTOMETRY AND THE FLUORESCENT DYE PERIDININ CHLOROPHYLL-A PROTEIN [J].
AFAR, B ;
MERRILL, J ;
CLARK, EA .
JOURNAL OF CLINICAL IMMUNOLOGY, 1991, 11 (05) :254-261
[2]  
BROWMAN GP, 1986, BLOOD, V68, P900
[3]   SIMULTANEOUS IDENTIFICATION OF 8 LEUKOCYTE SUBSETS OF HUMAN PERIPHERAL-BLOOD USING 3-COLOR IMMUNOFLUORESCENCE FLOW CYTOMETRIC ANALYSIS [J].
CARAYON, P ;
BORD, A ;
RAYMOND, M .
JOURNAL OF IMMUNOLOGICAL METHODS, 1991, 138 (02) :257-264
[4]   REPORT OF THE NATIONAL CANCER INSTITUTE-SPONSORED WORKSHOP ON DEFINITIONS OF DIAGNOSIS AND RESPONSE IN ACUTE MYELOID-LEUKEMIA [J].
CHESON, BD ;
CASSILETH, PA ;
HEAD, DR ;
SCHIFFER, CA ;
BENNETT, JM ;
BLOOMFIELD, CD ;
BRUNNING, R ;
GALE, RP ;
GREVER, MR ;
KEATING, MJ ;
SAWITSKY, A ;
STASS, S ;
WEINSTEIN, H ;
WOODS, WG .
JOURNAL OF CLINICAL ONCOLOGY, 1990, 8 (05) :813-819
[5]   CELL-SURFACE ANTIGENS ON HUMAN MARROW-CELLS - DISSECTION OF HEMATOPOIETIC DEVELOPMENT USING MONOCLONAL-ANTIBODIES AND MULTIPARAMETER FLOW-CYTOMETRY [J].
CIVIN, CI ;
LOKEN, MR .
INTERNATIONAL JOURNAL OF CELL CLONING, 1987, 5 (04) :267-288
[6]  
DREXLER HG, 1987, LEUKEMIA, V1, P697
[7]  
FOON KA, 1986, BLOOD, V68, P1
[8]  
HERRMANN F, 1983, BLUT, V7, P157
[9]   ESTABLISHING OPTIMAL LYMPHOCYTE GATES FOR IMMUNOPHENOTYPING BY FLOW-CYTOMETRY [J].
LOKEN, MR ;
BROSNAN, JM ;
BACH, BA ;
AULT, KA .
CYTOMETRY, 1990, 11 (04) :453-459
[10]   A SINGLE LASER FLOW-CYTOMETRY METHOD TO EVALUATE THE BINDING OF 3 ANTIBODIES [J].
MAURER, D ;
FELZMANN, T ;
KNAPP, W .
JOURNAL OF IMMUNOLOGICAL METHODS, 1990, 135 (1-2) :43-47