OBJECTIVE QUANTIFICATION OF SPASTIC HYPERTONIA - CORRELATION WITH CLINICAL FINDINGS

被引:226
作者
KATZ, RT
ROVAI, GP
BRAIT, C
RYMER, WZ
机构
[1] NORTHWESTERN UNIV,SCH MED,DEPT REHABIL MED,CHICAGO,IL 60611
[2] NORTHWESTERN UNIV,SCH MED,DEPT PHYSIOL,CHICAGO,IL 60611
[3] REHABIL INST CHICAGO,SENSORY MOTOR PERFORMANCE PROGRAM,CHICAGO,IL 60611
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 1992年 / 73卷 / 04期
关键词
HEMIPLEGIA; HYPERTONIA; SPASTICITY;
D O I
10.1016/0003-9993(92)90007-J
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
To develop a reliable and objective technique for quantifying spastic hypertonia, ten chronically hemiplegic patients with varying degrees of spasticity were studied on three occasions during several weeks. The modified Ashworth scale, a clinical assessment of extremity tone, was performed before and after each of the following objective tests: (1) torque and EMG measurements during ramp and hold angular displacement about the elbow, (2) pendulum test of the lower extremity, and (3) H/M ratio studies of upper and lower extremities. Subject motor function was also quantified using the Fugl-Meyer motor assessment scale. A regression analysis was performed to determine how successfully each of the objective measures correlated with the clinical yardstick, the modified Ashworth scale. A similar correlation between the objective measures and the Fugl-Meyer motor assessment scale was performed. Temporal reproducibility of a test for a given subject was evaluated by performing an ANOVA of repeated measures for each test over the three study sessions in a given subject. We conclude that (1) both the ramp and hold threshold measurements and pendulum test offer acceptable objective measures of spastic hypertonia since they correlate closely with clinical perception, (2) the Fugl-Meyer motor assessment scale also correlates closely with the severity of spastic tone, and (3) objective measures of spastic hypertonia are often surprisingly reproducible when repeatedly applied to a selected group of chronic hemiplegic patients with long-standing spasticity.
引用
收藏
页码:339 / 347
页数:9
相关论文
共 37 条
[1]   H REFLEX IN NORMAL, SPASTIC, AND RIGID SUBJECTS [J].
ANGEL, RW ;
HOFMANN, WW .
ARCHIVES OF NEUROLOGY, 1963, 8 (06) :591-&
[2]  
ASHWORTH B, 1964, PRACTITIONER, V192, P540
[3]   TESTING AND MODELING OF SPASTICITY [J].
BAJD, T ;
BOWMAN, B .
JOURNAL OF BIOMEDICAL ENGINEERING, 1982, 4 (02) :90-96
[4]  
BAJD T, 1984, J BIOMED ENG, V6, P9, DOI 10.1016/0141-5425(84)90003-7
[5]  
BERGLUND K, 1986, SCAND J REHABIL MED, V18, P155
[6]   MODIFIED PENDULOUSNESS TEST TO ASSESS TONUS OF THIGH MUSCLES IN SPASTICITY [J].
BOCZKO, M ;
MUMENTHALER, M .
NEUROLOGY, 1958, 8 (11) :846-851
[7]   INTERRATER RELIABILITY OF A MODIFIED ASHWORTH SCALE OF MUSCLE SPASTICITY [J].
BOHANNON, RW ;
SMITH, MB .
PHYSICAL THERAPY, 1987, 67 (02) :206-207
[8]   VARIABILITY AND RELIABILITY OF THE PENDULUM TEST FOR SPASTICITY USING A CYBEX-II ISOKINETIC DYNAMOMETER [J].
BOHANNON, RW .
PHYSICAL THERAPY, 1987, 67 (05) :659-661
[9]   DOES THE WARTENBERG PENDULUM TEST DIFFERENTIATE QUANTITATIVELY BETWEEN SPASTICITY AND RIGIDITY - A STUDY IN ELDERLY STROKE AND PARKINSON PATIENTS [J].
BROWN, RA ;
LAWSON, DA ;
LESLIE, GC ;
MACARTHUR, A ;
MACLENNAN, WJ ;
MCMURDO, MET ;
MUTCH, WJ ;
PART, NJ .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1988, 51 (09) :1178-1186
[10]   OBSERVATIONS ON THE APPLICABILITY OF THE WARTENBERG PENDULUM TEST TO HEALTHY, ELDERLY SUBJECTS [J].
BROWN, RA ;
LAWSON, DA ;
LESLIE, GC ;
PART, NJ .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1988, 51 (09) :1171-1177