MEASUREMENT OF CORONARY AND PERIPHERAL ARTERY FLOW BY INTRAVASCULAR ULTRASOUND AND PULSED DOPPLER VELOCIMETRY

被引:10
|
作者
EICHHORN, EJ [1 ]
ALVAREZ, LG [1 ]
JESSEN, ME [1 ]
FASS, SM [1 ]
CHAO, RY [1 ]
HAAGEN, D [1 ]
GRAYBURN, PA [1 ]
机构
[1] UNIV TEXAS,SW MED CTR,DEPT INTERNAL MED,DIV CARDIOL,DALLAS,TX 75216
来源
AMERICAN JOURNAL OF CARDIOLOGY | 1992年 / 70卷 / 04期
关键词
D O I
10.1016/0002-9149(92)91208-L
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Traditional catheterization laboratory assessment of coronary artery disease has consisted of coronary angiography with or without quantitative coronary assessment. Although such information is clinically important, qualitative coronary angiography is limited by inter-observer variability,1 and quantitative assessment may not provide functional information such as coronary flow. Techniques to assess coronary artery flow in the catheterization laboratory have included coronary sinus thermodilution (CST),2,3 digital subtraction angiography4 and xenon washout techniques.5 These techniques have significant drawbacks, including inability to measure beat-to-beat variations.
引用
收藏
页码:542 / 545
页数:4
相关论文
共 50 条
  • [21] NONINVASIVE MEASUREMENT OF VELOCITY PROFILES AND BLOOD-FLOW IN COMMON CAROTID-ARTERY BY PULSED DOPPLER ULTRASOUND
    KELLER, HM
    MEIER, WE
    ANLIKER, M
    KUMPE, DA
    STROKE, 1976, 7 (04) : 370 - 377
  • [22] Role of coronary artery lumen enlargement in improving coronary blood flow after balloon angioplasty and stenting: A combined intravascular ultrasound Doppler flow and imaging study
    Kern, MJ
    Dupouy, P
    Drury, JH
    Aguirre, FV
    Aptecar, E
    Bach, RG
    Caracciolo, EA
    Donohue, TJ
    Rande, JLD
    Geschwind, HJ
    Mechem, CJ
    Kane, G
    Teiger, E
    Wolford, TL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (07) : 1520 - 1527
  • [23] Slug flow identification using ultrasound Doppler velocimetry
    Wang, Song-Qing
    Xu, Ke-Wei
    Kim, Hyoung-Bum
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 148
  • [24] Measurement capabilities of planar Doppler velocimetry using pulsed lasers
    McKenzie, RL
    APPLIED OPTICS, 1996, 35 (06): : 948 - 964
  • [25] PULSED DOPPLER ULTRASOUND IMAGING OF THE VERTEBRAL ARTERY
    WOOD, CPL
    MEIRE, HB
    BRITISH JOURNAL OF RADIOLOGY, 1980, 53 (634): : 1028 - 1028
  • [26] DIAGNOSIS OF CORONARY-ARTERY FISTULA BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY, PULSED DOPPLER ULTRASOUND AND COLOR FLOW IMAGING
    VELVIS, H
    SCHMIDT, KG
    SILVERMAN, NH
    TURLEY, K
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (04) : 968 - 976
  • [27] Invasive assessment of the coronary circulation: intravascular ultrasound and Doppler
    Newby, DE
    Fox, KAA
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2002, 53 (06) : 561 - 575
  • [28] Utilization of intravascular ultrasound in coronary artery disease
    Ata, Necmi
    Goktekin, Omer
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2008, 8 : 15 - 22
  • [29] Intravascular ultrasound during coronary artery stenting
    Matchin, YG
    Savtchenko, AP
    Belenkov, YN
    KARDIOLOGIYA, 2000, 40 (10) : 56 - 62
  • [30] Coronary artery flow monitoring: The value of intravascular Doppler for detection of complications after interventions
    Anderson, HV
    Kirkeeide, RL
    Willerson, JT
    Smalling, RW
    Schroth, G
    EUROPEAN HEART JOURNAL, 1995, 16 : 93 - 96