COMPARISON OF VARIOUS METHODS FOR THE ENUMERATION OF BLOOD-CELLS IN URINE

被引:15
作者
MCGINLEY, M [1 ]
WONG, LL [1 ]
MCBRIDE, JH [1 ]
RODGERSON, DO [1 ]
机构
[1] UNIV CALIF LOS ANGELES,SCH MED,DEPT PATHOL & LAB MED,CLIN CHEM LAB,LOS ANGELES,CA 90024
关键词
URINALYSIS; WBC COUNTS; RBC COUNTS;
D O I
10.1002/jcla.1860060604
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
This study compared the use of conventional urine microscopy, the KOVA system, Neubauer hemacytometry, and the Yellow IRIS for the determination of white blood cell (WBC) and red blood cell (RBC) counts in urine samples. Both KOVA WBC and RBC counts correlated better with the IRIS counts than with conventional microscopy. KOVA WBC counts correlated with Neubauer hemacytometry to the same degree as they did with IRIS WBC counts. The RBC count correlation was fairly similar between KOVA, hemacytometry, and the conventional method. It was concluded that the KOVA system is a suitable replacement for conventional urine microscopy.
引用
收藏
页码:359 / 361
页数:3
相关论文
共 3 条
[1]  
NELSON DA, 1979, CLIN DIAGNOSIS MANAG, P857
[2]  
SCHUMANN GB, 1986, J MED TECHNOL, V3, P54
[3]  
WINKEL P, 1974, CLIN CHEM, V20, P436