TIME-REVERSAL PROCESSING IN ULTRASONIC NONDESTRUCTIVE TESTING

被引:103
作者
CHAKROUN, N
FINK, MA
WU, F
机构
[1] Laboratoire Ondes et Acoustique, ESPCI, Universite Paris VII, 75005 Paris
关键词
D O I
10.1109/58.476552
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this paper, we present a novel and completely different approach to focusing on defects beneath plane or curved surfaces: the time reversal mirror method. The time reversal technique is based on the concept of time reversal of ultrasonic fields and takes into account both the phase and modulus information coming from the defect, This technique is self-adaptative and requires only the presence of a target in the solid sample. In highly scattering media, it is shown that the time reversal process allows a new approach to speckle noise reduction. Experimental results obtained with a 121-channel time reversal mirror on titanium and duralumin samples will be presented. They demonstrate the ability of time reversal to compensate for the distortions induced by liquid-solid interfaces of different geometries and to detect small defects in a noisy background.
引用
收藏
页码:1087 / 1098
页数:12
相关论文
共 11 条