MASS-TRANSFER EFFECTS ON DROPLET PHENOMENA AND EXTRACTION COLUMN HYDRODYNAMICS REVISITED

被引:17
作者
TSOURIS, C [1 ]
TAVLARIDES, LL [1 ]
机构
[1] SYRACUSE UNIV,DEPT CHEM ENGN & MAT SCI,SYRACUSE,NY 13244
基金
美国国家科学基金会;
关键词
D O I
10.1016/0009-2509(93)80055-U
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The effect of solute mass transfer between the two liquid phases on the drop size distribution and holdup profiles of the dispersed phase in a multistage extraction column is experimentally investigated in this article. Experimental results of the drop size distribution, dispersed-phase volume fraction (holdup), and concentration profiles are obtained for both directions of mass transfer. The drop size distribution is measured by a photomicrographic technique, the holdup profile is measured by an ultrasonic technique, and the concentration profiles are measured by refraction index measurements. A strong influence of the mass-transfer direction on drop size and holdup has been found. The results are in qualitative agreement with the observations of other investigators. Mass transfer of butyric acid from toluene (dispersed) to water (continuous) produced larger drop sizes and lower values of the dispersed-phase holdup than for the equilibrated toluene-water system. For mass transfer of butyric acid from water (continuous) to toluene (dispersed) smaller drop sizes and higher holdup values are observed than for the equilibrated toluene-water system. This behavior significantly affects the performance of the extractor and indicates the necessity for more studies to determine the physics of the phenomenon and to model these processes appropriately.
引用
收藏
页码:1503 / 1515
页数:13
相关论文
共 50 条
  • [31] AXIAL MIXING AND MASS-TRANSFER IN A VIBRATING PERFORATED PLATE EXTRACTION COLUMN
    BAIRD, MHI
    RAO, NVR
    VIJAYAN, S
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1992, 70 (01) : 69 - 76
  • [32] MASS-TRANSFER AND POWER-CONSUMPTION IN A RECIPROCATING PLATE EXTRACTION COLUMN
    IOANNOU, J
    HAFEZ, M
    HARTLAND, S
    INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1977, 16 (01): : 155 - 155
  • [33] Reverse micellar mass-transfer processes: Spray column extraction of lysozyme
    Lye, GJ
    Asenjo, JA
    Pyle, DL
    AICHE JOURNAL, 1996, 42 (03) : 713 - 726
  • [34] HYDRODYNAMICS AND MASS-TRANSFER IN ASPERGILLUS-NIGER FERMENTATIONS IN BUBBLE COLUMN AND LOOP BIOREACTORS
    ALLEN, DG
    ROBINSON, CW
    BIOTECHNOLOGY AND BIOENGINEERING, 1989, 34 (06) : 731 - 740
  • [35] MASS-TRANSFER EFFICIENCIES OF COLUMN CONTACTORS IN SUPERCRITICAL EXTRACTION SERVICE.
    Lahiere, Richard J.
    Fair, James R.
    Industrial and Engineering Chemistry Research, 1987, 26 (10) : 2086 - 2092
  • [36] ENZYME MASS-TRANSFER COEFFICIENT IN A SIEVE-PLATE EXTRACTION COLUMN
    BHAWSAR, PCM
    PANDIT, AB
    SAWANT, SB
    JOSHI, JB
    CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1994, 55 (1-2): : B1 - B17
  • [37] A MODEL FOR SIMULATION OF HYDRODYNAMICS AND MASS-TRANSFER IN EXTRACTION COLUMNS FILLED WITH A REGULAR PACKING
    STEINER, L
    BERTSCHMANN, H
    HARTLAND, S
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 1995, 73 (A5) : 542 - 550
  • [38] SURFACE RENEWAL PHENOMENA IN LIQUID-LIQUID DROPLET SYSTEMS WITH AND WITHOUT MASS-TRANSFER
    THORNTON, JD
    ANDERSON, TJ
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1981, 24 (11) : 1847 - 1848
  • [39] The effects of surfactant on the mass transfer in extraction column
    Lee, YL
    Maa, JR
    Yang, YM
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1998, 31 (03) : 340 - 346
  • [40] HYDRODYNAMICS AND MASS TRANSFER IN A PLATE COLUMN
    RODINOW, AI
    PATZELT, H
    CHEMISCHE TECHNIK, 1969, 21 (04): : 250 - &