END-TIDAL CARBON-DIOXIDE MEASUREMENT DURING PEDIATRIC ANESTHESIA - THE INFLUENCE OF SITE OF MEASUREMENT AND RESPIRATORY RATE

被引:0
作者
FRETSCHNER, R
WARTH, H
DEUSCH, H
KLOSS, T
机构
来源
ANAESTHESIST | 1992年 / 41卷 / 08期
关键词
ANESTHESIA; PEDIATRIC; CARBON DIOXIDE; ALVEOLAR; END-TIDAL; CAPILLARY; MONITORING; CAPNOGRAPHY; VENTILATION; MECHANICAL;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective. To evaluate the influences of site of measurement, respiratory rate, and tidal volume on end-tidal PCO2 measurement in children ventilated with a non-rebreathing system. Setting. Paediatric surgical patients of a university hospital. Patients. Thirty-one children scheduled for major abdominal or urogenital surgery; weight varying between 2.2 and 9.8 kg. Interventions and methods. During a relative steady-state situation, end-tidal carbon dioxide partial pressure (PetCO2) was measured at the proximal and distal ends of the endotracheal tube by a sidestream analyser (Datex, Normocap) and between the proximal end of the tube and the Y-piece of the ventilator by a mainstream analyser (Hewlett Packard, HP14265A). PetCO2 was corrected for water vapor and calculated as partial pressure at a barometric pressure of 760 mmHg. At the same time, capillary blood was taken for blood gas analysis. The capillary-end-tidal PCO2 gradient [dPCO2(cap-et)] was computed to compare the three capnometric methods. Statistical analysis was performed with the Friedmann test. Correlations were calculated by means of the least-square fitting method and significance of the correlation was checked with the F-test. Results. dPCO2 (cap-et) did not differ significantly in children with more than 6 kg body weight. In patients less than 6 kg, however, the three capnometric methods revealed significantly different dPCO2 (cap-et) values (P < 0.01): dPCO2 (cap-et) was 3.0+/-4.7 mmHg at the distal end of the endotracheal tube, 5.8+/-4.6 mmHg at the proximal end, and 8.7+/-4.6 mmHg between the proximal sidestream connector and the Y-piece of the ventilator. There was no correlation between tidal volume and dPCO2 (cap-et) (Fig. 1), however, a significant relation was found between respiratory rate and dPCO2 (cap-et) (Fig. 2) and between respiratory rate and the PCO2 difference between the distal and proximal ends of the endotracheal tube (Fig. 3). Conclusions. Even in a non-rebreathing system, capnometry is influenced by the site of measurement. In small children with body weight below 6 kg, analysis of an endotracheal sample may provide the best PetCO2 values. In our opinion, dPCO2 (capet) in the present investigation was not caused by rebreathing or by pendelluft (a significant correlation between dPCO2 (cap-et) and tidal volume would then have been expected), but was mainly due to ventilation-perfusion mismatch. This may result from high respiratory rates causing inadequate ventilation of lung regions with long time-constants.
引用
收藏
页码:463 / 467
页数:5
相关论文
共 50 条
  • [41] Associations Between End-Tidal Carbon Dioxide During Pediatric Cardiopulmonary Resuscitation, Cardiopulmonary Resuscitation Quality, and Survival
    Morgan, Ryan W.
    Reeder, Ron W.
    Bender, Dieter
    Cooper, Kellimarie K.
    Friess, Stuart H.
    Graham, Kathryn
    Meert, Kathleen L.
    Mourani, Peter M.
    Murray, Robert
    Nadkarni, Vinay M.
    Nataraj, Chandrasekhar
    Palmer, Chella A.
    Srivastava, Neeraj
    Tilford, Bradley
    Wolfe, Heather A.
    Yates, Andrew R.
    Berg, Robert A.
    Sutton, Robert M.
    CIRCULATION, 2024, 149 (05) : 367 - 378
  • [42] INTRAOPERATIVE END-TIDAL CARBON-DIOXIDE VALUES AND DERIVED CALCULATIONS CORRELATED WITH OUTCOME - PROGNOSIS AND CAPNOGRAPHY
    DOMSKY, M
    WILSON, RF
    HEINS, J
    CRITICAL CARE MEDICINE, 1995, 23 (09) : 1497 - 1503
  • [43] CAN PULSE OXIMETRY AND END-TIDAL CAPNOGRAPHY REFLECT ARTERIAL OXYGENATION AND CARBON-DIOXIDE ELIMINATION DURING LAPAROSCOPIC CHOLECYSTECTOMY
    BARAKA, A
    JABBOUR, S
    HAMMOUD, R
    AOUAD, M
    NAJJAR, F
    KHOURY, G
    SIBAI, A
    SURGICAL LAPAROSCOPY & ENDOSCOPY, 1994, 4 (05) : 353 - 356
  • [44] Levels of end-tidal carbon dioxide are low despite normal respiratory rate in individuals with long COVID
    Wood, Jamie
    Tabacof, Laura
    Tosto-Mancuso, Jenna
    McCarthy, Dayna
    Kontorovich, Amy
    Putrino, David
    JOURNAL OF BREATH RESEARCH, 2022, 16 (01)
  • [45] The impact of ventilation rate on end-tidal carbon dioxide level during manual cardiopulmonary resuscitation
    Ruiz de Gauna, Sofia
    Julio Gutierrez, Jose
    Ruiz, Jesus
    Leturiondo, Mikel
    Azcarate, Izaskun
    Maria Gonzalez-Otero, Digna
    Corcuera, Carlos
    Russell, James Knox
    Daya, Mohamud Ramzan
    RESUSCITATION, 2020, 156 : 215 - 222
  • [46] ARTERIAL TO END-TIDAL CARBON-DIOXIDE TENSION DIFFERENCE DURING LAPAROSCOPY - MAGNITUDE AND EFFECT OF ANESTHETIC TECHNIQUE
    BRAMPTON, WJ
    WATSON, RJ
    ANAESTHESIA, 1990, 45 (03) : 210 - 214
  • [47] THE EFFECT OF DIFFERENT END-TIDAL VOLATILE AGENT AND CARBON-DIOXIDE CONCENTRATIONS UPON THE INCIDENCE OF POSTOPERATIVE SHIVERING
    HARWOOD, RJ
    SINGH, P
    CARTWRIGHT, DP
    CROSSLEY, AWA
    ANAESTHESIA, 1995, 50 (09) : 786 - 788
  • [48] MONITORING CARDIOPULMONARY-RESUSCITATION - ROLE OF BLOOD AND END-TIDAL CARBON-DIOXIDE TENSION
    GASMAN, JD
    FISHMAN, RS
    RAFFIN, TA
    CRITICAL CARE MEDICINE, 1995, 23 (05) : 799 - 800
  • [49] End tidal carbon dioxide measurement using an electro acoustic sensor
    Folke, M
    Hök, B
    Ekström, M
    Bäcklund, Y
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 3452 - 3455
  • [50] Continuous End-Tidal Carbon Dioxide Monitoring during Resuscitation of Asphyxiated Term Lambs
    Chandrasekharan, Praveen Kumar
    Rawat, Munmun
    Nair, Jayasree
    Gugino, Sylvia F.
    Koenigsknecht, Carmon
    Swartz, Daniel D.
    Vali, Payam
    Mathew, Bobby
    Lakshminrusimha, Satyan
    NEONATOLOGY, 2016, 109 (04) : 265 - 273