END-TIDAL CARBON-DIOXIDE MEASUREMENT DURING PEDIATRIC ANESTHESIA - THE INFLUENCE OF SITE OF MEASUREMENT AND RESPIRATORY RATE

被引:0
作者
FRETSCHNER, R
WARTH, H
DEUSCH, H
KLOSS, T
机构
来源
ANAESTHESIST | 1992年 / 41卷 / 08期
关键词
ANESTHESIA; PEDIATRIC; CARBON DIOXIDE; ALVEOLAR; END-TIDAL; CAPILLARY; MONITORING; CAPNOGRAPHY; VENTILATION; MECHANICAL;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective. To evaluate the influences of site of measurement, respiratory rate, and tidal volume on end-tidal PCO2 measurement in children ventilated with a non-rebreathing system. Setting. Paediatric surgical patients of a university hospital. Patients. Thirty-one children scheduled for major abdominal or urogenital surgery; weight varying between 2.2 and 9.8 kg. Interventions and methods. During a relative steady-state situation, end-tidal carbon dioxide partial pressure (PetCO2) was measured at the proximal and distal ends of the endotracheal tube by a sidestream analyser (Datex, Normocap) and between the proximal end of the tube and the Y-piece of the ventilator by a mainstream analyser (Hewlett Packard, HP14265A). PetCO2 was corrected for water vapor and calculated as partial pressure at a barometric pressure of 760 mmHg. At the same time, capillary blood was taken for blood gas analysis. The capillary-end-tidal PCO2 gradient [dPCO2(cap-et)] was computed to compare the three capnometric methods. Statistical analysis was performed with the Friedmann test. Correlations were calculated by means of the least-square fitting method and significance of the correlation was checked with the F-test. Results. dPCO2 (cap-et) did not differ significantly in children with more than 6 kg body weight. In patients less than 6 kg, however, the three capnometric methods revealed significantly different dPCO2 (cap-et) values (P < 0.01): dPCO2 (cap-et) was 3.0+/-4.7 mmHg at the distal end of the endotracheal tube, 5.8+/-4.6 mmHg at the proximal end, and 8.7+/-4.6 mmHg between the proximal sidestream connector and the Y-piece of the ventilator. There was no correlation between tidal volume and dPCO2 (cap-et) (Fig. 1), however, a significant relation was found between respiratory rate and dPCO2 (cap-et) (Fig. 2) and between respiratory rate and the PCO2 difference between the distal and proximal ends of the endotracheal tube (Fig. 3). Conclusions. Even in a non-rebreathing system, capnometry is influenced by the site of measurement. In small children with body weight below 6 kg, analysis of an endotracheal sample may provide the best PetCO2 values. In our opinion, dPCO2 (capet) in the present investigation was not caused by rebreathing or by pendelluft (a significant correlation between dPCO2 (cap-et) and tidal volume would then have been expected), but was mainly due to ventilation-perfusion mismatch. This may result from high respiratory rates causing inadequate ventilation of lung regions with long time-constants.
引用
收藏
页码:463 / 467
页数:5
相关论文
共 50 条
  • [1] END-TIDAL CARBON-DIOXIDE MEASUREMENT IN INFANTS AND CHILDREN DURING AND AFTER GENERAL-ANESTHESIA
    CAMPBELL, FA
    MCLEOD, ME
    BISSONNETTE, B
    SWARTZ, JS
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1994, 41 (02): : 107 - 110
  • [2] A COMPARISON OF TRANSCUTANEOUS, END-TIDAL AND ARTERIAL MEASUREMENTS OF CARBON-DIOXIDE DURING GENERAL-ANESTHESIA
    REID, CW
    MARTINEAU, RJ
    MILLER, DR
    HULL, KA
    BAINES, J
    SULLIVAN, PJ
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1992, 39 (01): : 31 - 36
  • [3] STABILITY OF THE ARTERIAL TO END-TIDAL CARBON-DIOXIDE DIFFERENCE DURING ANESTHESIA FOR PROLONGED NEUROSURGICAL PROCEDURES
    SHARMA, SK
    MCGUIRE, GP
    CRUISE, CJE
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1995, 42 (06): : 498 - 503
  • [4] END-TIDAL CARBON-DIOXIDE PRESSURE IN NEONATES AND INFANTS MEASURED BY ASPIRATION AND FLOW-THROUGH CAPNOGRAPHY
    BADGWELL, JM
    HEAVNER, JE
    JOURNAL OF CLINICAL MONITORING, 1991, 7 (04): : 285 - 288
  • [5] END-TIDAL CARBON-DIOXIDE AS AN INDICATOR OF ARTERIAL CARBON-DIOXIDE IN NEUROINTENSIVE CARE PATIENTS
    RUSSELL, GB
    GRAYBEAL, JM
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 1992, 4 (04) : 245 - 249
  • [6] End-tidal carbon dioxide measurement and breathing system filters
    Hardman, JG
    Curran, J
    Mahajan, RP
    ANAESTHESIA, 1997, 52 (07) : 646 - 648
  • [7] COMPARISON OF END-TIDAL AND ARTERIAL CARBON-DIOXIDE MEASUREMENTS DURING ANESTHESIA WITH THE LARYNGEAL MASK AIRWAY
    HICKS, IR
    SONI, NC
    SHEPHARD, JN
    BRITISH JOURNAL OF ANAESTHESIA, 1993, 71 (05) : 734 - 735
  • [8] End-Tidal Carbon Dioxide Measurement during Pediatric Polysomnography: Signal Quality, Association with Apnea Severity, and Prediction of Neurobehavioral Outcomes
    Paruthi, Shalini
    Rosen, Carol L.
    Wang, Rui
    Weng, Jia
    Marcus, Carole L.
    Chervin, Ronald D.
    Stanley, Jeffrey J.
    Katz, Eliot S.
    Amin, Raouf
    Redline, Susan
    SLEEP, 2015, 38 (11) : 1719 - 1726
  • [9] SENSITIVITY OF A DISPOSABLE END-TIDAL CARBON-DIOXIDE DETECTOR
    JONES, BR
    DORSEY, MJ
    JOURNAL OF CLINICAL MONITORING, 1991, 7 (03): : 268 - 270
  • [10] ACCURACY OF END-TIDAL CARBON-DIOXIDE TENSION ANALYZERS
    RAEMER, DB
    CALALANG, I
    JOURNAL OF CLINICAL MONITORING, 1991, 7 (02): : 195 - 208